Évaluation des techniques de couplage pour les systèmes de conditionnement d'air et de froid utilisant une méthode de mesure de la concentration.
Evaluation of joining techniques for air-conditioning and refrigeration systems using concentration accumulation method.
Résumé
This paper is based on the study performed for AHRTI (The Air-Conditioning, Heating and Refrigeration Technology Institute) on joining techniques assessment. The purpose of this research program is to develop a guideline to minimize refrigerant leaks by using high-performance joints to ensure that designs and products are adequate to provide a leak-tight system. Sealing technologies of commonly used components (such as solenoid valves, service valves, flare fittings, filters, TXVs, sight glasses, etc.) of air-conditioning and refrigeration industry have been identified in detail. Leak flow rates of those joints have been determined using the method of concentration measurement by infrared spectrophotometry in a test chamber with high testing accuracy. A large number of tests have been performed to investigate the leakage level of these components. Measurement of valves before and after manipulations, influence of torques, and leak tightness of pressure relief valves after pressure relief have been studied as well. Results show that if components are well chosen and properly mounted, the leak flow rates of refrigeration systems can be as low as some few grams/year, but several components are, by design, very sensitive to improper mounting or require torque wrench.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Evaluation of joining techniques for air-conditioning and refrigeration systems using concentration accumulation method.
- Identifiant de la fiche : 30012405
- Langues : Anglais
- Sujet : Généralités
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Date d'édition : 02/08/2014
Liens
Voir d'autres communications du même compte rendu (119)
Voir le compte rendu de la conférence
-
Détection de fuites et tests d'étanchéité.
- Auteurs : SCHNERR T., SEIDEL R.
- Date : 2016
- Langues : Français
- Source : Cool & Comfort
Voir la fiche
-
Refrigerant release estimation.
- Date : 2008
- Langues : Anglais
- Source : Cold Front - vol. 8 - n. 1
Voir la fiche
-
Assessment of leakage rate and durability of fi...
- Auteurs : ELBEL S., LAWRENCE L., RAJ S.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Confinement des installations frigorifiques : r...
- Auteurs : HUCHET A., MORIO Y., CAZAURAN X., et al.
- Date : 03/2012
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 102 - n. 1121
Voir la fiche
-
Evaluation of refrigerants leakage ratios based...
- Auteurs : TOMLEIN P., TOMLEIN M.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche