In order to maintain a good indoor environment, fresh air is essential for audience in theatre buildings due to the high occupant density. Apart from mechanical fresh air, uncontrolled air leakage across building exterior (i.e., air infiltration) is also a source of outdoor fresh air. Therefore, assessing air infiltration rate is very necessary for determining total fresh air rate and avoiding excessive ventilation. However, the commonly used method to assess infiltration rate is very complex to implement. In this paper, we propose a convenient method to assess infiltration rate based on the mass balance of particulate matters. Given the ubiquity of particulate matters in the outdoor environment and being cost-free, this method is able to avoid the disadvantages of traditional methods. PM2.5 is chosen to establish the mass balance. Infiltration and total fresh air rates of a concert hall were measured and analyzed using the proposed method.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Assessing fresh air rate for theatre buildings using particle mass balance principle.
- Identifiant de la fiche : 30026796
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.1626
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Qualité de l'air intérieur
- Mots-clés : Air neuf; Immeuble; Mesure; Ventilation mécanique contrôlée; Ventilation; Qualité de l'air; Particule; Experimentation; Concentration
-
Control of indoor fine particle concentration i...
- Auteurs : VIALLE J. P., PETIT P., HERVE G., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
On the study of the indoor environment in priva...
- Auteurs : DORIZAS P. V., ASSIMAKOPOULOS M. N., SANTAMOURIS M.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Study of penetration of outdoor fine particles ...
- Auteurs : LIU X., ZHAI Z., FACCIOLA N. A., et al.
- Date : 23/06/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
Voir la fiche
-
Measuring IAQ parameters.
- Auteurs : BEARG D. W.
- Date : 08/2008
- Langues : Anglais
- Source : HPAC Engineering - vol. 80 - n. 8
Voir la fiche
-
A comparative analysis of the indoor air qualit...
- Auteurs : MUMOVIC D., DAVIES M., PEARSON C., et al.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche