Évaluation expérimentale de la formation de givre.

Experimental evaluation of the frost formation.

Numéro : pap. 2195

Auteurs : TASHIRO Y., HAMADA M.

Résumé

Frost formation on an evaporator causes significant problems by decreasing inlet air flow. It is important for a precise prediction to understand the dominant factor of the frost formation. In this paper, the frost layer on the cold plate is experimentally obtained with different velocities while maintaining a surface temperature at -20 degrees Celsius. The mass and height of the frost layer is measured throughout the experiment. The frost mass rate depends strongly on the absolute humidity and inlet air velocity. The obtained frost density depends on the relative humidity and inlet air velocity. Results show that the effect of the inlet air velocity is minor in regions with high relative humidity.

Documents disponibles

Format PDF

Pages : 5 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental evaluation of the frost formation.
  • Identifiant de la fiche : 30013257
  • Langues : Anglais
  • Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 14/07/2014

Liens


Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence