Évaluation expérimentale des performances des tuyères diphasiques pour les frigorigènes à faible PRP.

Experimental assessment of two-phase nozzle performance for low-GWP refrigerants.

Auteurs : JAKONCZUK P., SMIERCIEW K., DUDAR A., GAGAN J., BUTRYMOWICZ D.

Type d'article : Article de la RIF

Résumé

The performance of two-phase ejectors critically depends on the efficiency of motive nozzles, which govern the critical mass flow rate and overall system operation. However, accurately predicting nozzle performance under two-phase flow conditions remains challenging due to the complex interplay of thermodynamic and flow dynamics. This study addresses this issue by evaluating the performance coefficient of motive nozzles for three refrigerants: CO2, R600a, and R1234ze(E). Beyond ejector applications, understanding two-phase flow dynamics is essential for optimizing other key components, such as control valves and safety valves, which operate under similar conditions. Experiments conducted on a versatile test bench revealed significant differences in nozzle performance among the refrigerants. The performance coefficient ranged from 0.85 to 1.35 for CO2, 0.90 to 1.15 for R600a, and 0.92 to 1.22 for R1234ze(E). The Henry-Fauske model, used to predict critical mass flow, demonstrated an average deviation of 30 % for CO2, while deviations were much lower for R600a (9 %) and R1234ze(E) (4 %). The results highlight the sensitivity of the performance coefficient to the refrigerant thermodynamic properties, with CO2 exhibiting the most complex flow behavior due to its lower critical temperature and higher compressibility. This study provides quantitative insights into the performance of motive nozzles under two-phase flow and validates the applicability of simplified models for predicting critical flow rates. The findings contribute to optimizing ejector and valve design, emphasizing the need for further validation with additional refrigerants to enhance model universality.

Documents disponibles

Format PDF

Pages : 111-112

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental assessment of two-phase nozzle performance for low-GWP refrigerants.
  • Identifiant de la fiche : 30033826
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 173
  • Date d'édition : 05/2025
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2025.02.008