Résumé
Liquid-refrigerant return was divided into four cases on the basis of liquid refrigerant amount from an evaporator. Experiments were carried out to investigate the effect of liquid refrigerant return on the performance of a water chiller unit and a rolling rotor compressor. The results indicate that the refrigerating capacity increased by 6-10% and the COP increased by 8-16% for liquid refrigerant return with 0 superheat compared with the case in which the temperature difference was above 0. The system performance decreased with an increase in the amount of liquid-refrigerant return. The low liquid-refrigerant return amount would reduce the discharge temperature and enhance oil return effectively. In addition, the wear of the moving parts would be serious and the discharge valve life would decrease in the compressor when the amount of liquid refrigerant return reached a critical value.
Documents disponibles
Format PDF
Pages : pp. 22-34 (5 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2010-1432
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 31 - n. 4
- Date d'édition : 08/2010
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2010.04.022
Liens
Voir d'autres articles du même numéro (7)
Voir la source
Indexation
-
Thèmes :
Systèmes à compression;
Compresseurs;
Refroidisseurs d'eau - Mots-clés : Système frigorifique; Rotor; Refroidisseur; Experimentation; Frigorigène; Compresseur
-
Betriebserfahrungen mit Kompressionskälteanlage...
- Auteurs : BURANDT B., APLEY R., NOACK R.
- Date : 21/11/2001
- Langues : Allemand
- Source : DKV-Tagungsbericht Ulm. 2001.
Voir la fiche
-
A centrifugal compressor cooling system using w...
- Auteurs : SUESS J.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Sensitivity of refrigeration system performance...
- Auteurs : GRACE I. N., DATTA D., TASSOU S. A.
- Date : 03/2005
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 25 - n. 4
Voir la fiche
-
Energy efficiency of the thermocompression refr...
- Auteurs : SAREVSKI V. N., SAREVSKI M. N.
- Date : 06/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 4
- Formats : PDF
Voir la fiche
-
Water as refrigerant in cooling plants.
- Auteurs : THISGAARD P.
- Date : 03/1995
- Langues : Anglais
- Source : CADDET Energy Effic. Newsl. - n. 1