Facteurs de conversion permettant de comparer la performance de différents systèmes à débit de frigorigène variable.
Conversion factors for comparing the performance of variable refrigerant flow systems.
Numéro : pap. 2227
Auteurs : MATSUI E., KAMETANI S., NOBE T.
Résumé
Due to the growing concern about energy savings in recent years the Japan Industrial Standards (JIS) committee revised the performance rating of industrial air conditioning systems in October, 2006. The coefficient of performance (COP), the conventional factor, does not consider the actual operation of air conditioning systems corresponding to seasonal temperature changes. Instead it is evaluated under constant temperature conditions. In actual operation, the capacity and power consumption of cooling and heating varies according to outside air temperatures. As a result, the annual performance factor (APF) was adopted as the new criteria to evaluate energy savings performance. Under this method, model cases were designed in order to conduct proper evaluations that are approximately equal to real operation. Factors were estimated by calculations of annual total energy consumption and building thermal load. As the efficiency characteristics of the APF and COP are respectively indicated, calculation of conversion factors became necessary in order to compare their energy saving capabilities. In this study, the energy consumption and its characteristics of the APF and COP machines were calculated using the annual operating data of electric driven heat pumps (EHP) under equivalent load conditions. Effective efficiency was defined as a parameter to estimate conversion factors as follows: Effective efficiency = Annual effective generated heat / Annual energy consumption. Using these conversion factors, the performance of machines can be easily compared when evaluation standards change and new air conditioning systems are installed. Furthermore, this approach can also be applied to gas engine driven heat pumps (GHP).
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Conversion factors for comparing the performance of variable refrigerant flow systems.
- Identifiant de la fiche : 30019007
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 11/07/2016
Liens
Voir d'autres communications du même compte rendu (274)
Voir le compte rendu de la conférence
-
Points de vue sur la conception de la ventilati...
- Auteurs : ZHOU Z.
- Date : 05/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 277
- Formats : PDF
Voir la fiche
-
Conception et mise en service d’une régulation ...
- Auteurs : YU C., NIE X.
- Date : 12/2014
- Langues : Chinois
- Source : HV & AC - vol. 44 - n. 298
- Formats : PDF
Voir la fiche
-
Performance of VAV fan-powered terminal units: ...
- Auteurs : FURR J. C., O'NEAL D. L., DAVIS M. A., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche
-
Performance of VAV parallel fan-powered termina...
- Auteurs : FURR J. C., O'NEAL D. L., DAVIS M. A., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche
-
Performance of VAV series fan-powered terminal ...
- Auteurs : FURR J. C., O'NEAL D. L., DAVIS M. A., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche