Faisabilité d'un système frigorifique à absorption ammoniac-eau pour les bateaux de pêche.
Viabilidad de refrigeración por absorción con amoniaco-agua en barcos pesqueros.
Auteurs : PERANIC J., BOZUNOVIC A., PAVKOVIC B.
Type d'article : Article de périodique
Résumé
This article is the Spanish translation of an article presented at the IIR conference in Ohrid, Macedonia (see the Bulletin of the IIR, reference 2007-2318). The ammonia compression refrigeration system and the ammonia-water absorption refrigeration system powered by the heat recovered from engine exhaust gasses are designed and compared with an example of seawater refrigeration for medium-sized fishing boats. It has been shown in this paper that the single-stage absorption refrigeration plant can achieve better results in energy efficiency and in terms of environmental impact. Furthermore, it has been demonstrated that even lower total costs of the absorption system compared to a compression system can be achieved for the analyzed application. Drawbacks of absorption systems, such as high mass and volume do not allow wide application but they can be overcome by further research in absorption system optimization.
Documents disponibles
Format PDF
Pages : 28-35 (7 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Viabilidad de refrigeración por absorción con amoniaco-agua en barcos pesqueros.
- Identifiant de la fiche : 2008-2743
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 36 - n. 405
- Date d'édition : 07/2008
Liens
- Voir les traductions : The feasibility of ammonia-water absorption refrigeration for fishing vessels.
Voir d'autres articles du même numéro (7)
Voir la source
-
Sta se moze ocekivati od apsorpcione rashladne ...
- Auteurs : KOSI F., BURAZER J., MILOVANCEVIC U., et al.
- Date : 09/2011
- Langues : Serbe
- Source : KGH (Klimatizacija Grejanje Hladenje) - vol. 40 - n. 3
Voir la fiche
-
A HIGH EFFICIENCY AMMONIA-WATER ABSORPTION POWE...
- Auteurs : ROGDAKIS E. D., ANTONOPOULOS K. A.
- Date : 1991
- Langues : Anglais
- Source : Heat Recov. Syst. CHP - vol. 11 - n. 4
Voir la fiche
-
Influence de la performance de l'échangeur de c...
- Auteurs : ZHONG L., ZHAO W. Y., TAN Y. K.
- Date : 2001
- Langues : Chinois
- Source : Refrigeration - vol. 75 - n. 2
Voir la fiche
-
EVALUATION DE L'EFFICACITE THERMODYNAMIQUE DES ...
- Auteurs : TIMOFEEVSKIJ L. S.
- Date : 1984
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 7
Voir la fiche
-
The energy effectiveness of heat-consuming ther...
- Auteurs : POPOV A. V., KOROLKOV A. G.
- Date : 2003
- Langues : Anglais
- Source : J. Eng. Thermophys. - vol. 12 - n. 3
Voir la fiche