Document IIF
Hydrocarbure en tant que frigorigène de remplacement permettant la conservation d'énergie dans un système de conditionnement d'air.
Hydrocarbon refrigerant as an alternative refrigerant for energy conservation in an air conditioning system.
Auteurs : PASEK A. D., SUWONO A.
Résumé
Series of investigations were carried to find out the consequences of retrofitting the R22 AC system with hydrocarbon R290 refrigerant. The investigation includes the theoretical prediction on the effect of mixing R22 and R290, the alteration of R22 oil viscosity when R290 is used, and the observation of performance and total electric energy consumption of the retrofitted system and the building's. The result shows that R22 cannot be mixed with R290 and that the performance of the AC system is lower if R22/R290 mixtures were used as refrigerants. For that reason the R22 system has to be totally evacuated before it is filled with R290. The oil viscosity alteration is not significant. Hence, R290 can be filled into R22 system without oil replacement. The performance of retrofitted chillers is better. This is indicated by lower electric power consumption, and better cooling performance. The power saving in the retrofitted AC system gives significant reduction on total electric power consumption of a building.
Documents disponibles
Format PDF
Pages : 2004-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Hydrocarbon refrigerant as an alternative refrigerant for energy conservation in an air conditioning system.
- Identifiant de la fiche : 2005-2194
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Date d'édition : 01/08/2004
Liens
Voir d'autres communications du même compte rendu (105)
Voir le compte rendu de la conférence
Indexation
-
Expérience sur le remplacement du R22 par le R2...
- Auteurs : LI T., YANG J., ZENG Z., et al.
- Date : 08/2010
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 31 - n. 4
- Formats : PDF
Voir la fiche
-
Experimental assessment of HC-290 as a drop-in ...
- Auteurs : DEVOTTA S., PADALKAR A. S., SANE N. K.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Substitute HCFC-22 with hydrocarbons in air-con...
- Auteurs : WANG H., LI H., LIU F., et al.
- Date : 17/09/2002
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
Evolving an optimal composition of HFC-407C/HC-...
- Auteurs : JABARAJ D. B., NARENDRAN A., MOHAN LAL D., et al.
- Date : 03/2007
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 46 - n. 3
Voir la fiche
-
Experimental search on refrigerant and lubricat...
- Auteurs : HAN H., KAN A., JI J.
- Date : 20/05/2009
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
Voir la fiche