Document IIF

Impact d'un échangeur de chaleur interne sur la performance d'un système de conditionnement d'air mobile au R134a.

Effect of an internal heat exchanger on the performance of a R134a mobile air-conditioning system.

Auteurs : LI X. Z., CHE J., HRNJAK P.

Résumé

The paper presents an analysis of the role and effect of the internal heat exchanger (suction line heat exchanger) on performance (capacity and COP) of R134a mobile air-conditioning systems. Cycle analysis presented at the beginning is supported by experimental results. The system examined experimentally is a typical R134a air conditioning system for a medium size car. Compressor is reciprocating, condenser with microchannel tubes and evaporator is laminated plate/fin with single tank. Four cases were explored: baseline (without internal heat exchanger) and three others with different internal heat exchangers. Results demonstrate increases in capacity up to 7% and efficiency up to 7% compared with a baseline system (without internal heat exchanger) and COP and capacity maximizing exit quality in the range 0.98 to 1.0. Results also emphasize the role of pressure drop on the suction side.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Effect of an internal heat exchanger on the performance of a R134a mobile air-conditioning system.
  • Identifiant de la fiche : 2005-0413
  • Langues : Anglais
  • Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
  • Date d'édition : 17/08/2003

Liens


Voir d'autres communications du même compte rendu (398)
Voir le compte rendu de la conférence