
Document IIF
Influence de la configuration du générateur et de la pompe à bulles sur la performance d'un système frigorifique à absorption/diffusion.
The influence of the generator and bubble pump configuration on the performance of diffusion absorption refrigeration system.
Auteurs : ZOHAR A., JELINEK M., LEVY A., et al.
Type d'article : Article, Article de la RIF
Résumé
A diffusion absorption refrigeration (DAR) cycle is driven by heat and has no moving parts. These systems are both quiet and reliable and therefore often used in hotel rooms and offices. The disadvantage of these systems is a very low COP. Therefore, the configuration of the generator and bubble pump is of great importance. In order to increase the COP, it must utilize minimum heat as possible and desorb as much refrigerant as possible from the solution. In this work, a previous thermodynamic model was modified and validated by an experimental system. Detailed thermodynamic models for three generator and bubble pump configurations were developed: (a) heat input into the rich solution with no heat transfer to the poor solution; (b) heat input into the rich solution with heat transfer to the poor solution in the annular; and (c) heat input into the rich solution through the poor solution, thus also desorbing refrigerant from the poor solution, with heat transfer to the poor solution in the annular (a configuration which is used in commercial systems). The performance of three DAR systems, which differ in their generator and bubble pump configuration, was studied numerically. It was found that for the same heat input, the second configuration desorbed the highest amount of refrigerant and the first configuration desorbed the lowest. The third configuration proved to be less efficient compared to the second configuration in terms of COP. The first configuration resulted in the lowest performance, although heat is supplied directly to the rich solution.
Documents disponibles
Format PDF
Pages : 962-969
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The influence of the generator and bubble pump configuration on the performance of diffusion absorption refrigeration system.
- Identifiant de la fiche : 2008-2507
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 6
- Date d'édition : 09/2008
Liens
Voir d'autres articles du même numéro (17)
Voir la source
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Générateur; Amélioration; Bulle; Ammoniac-eau; Système à absorption; Pompe; Modélisation; Hydrogène; Gaz non condensable; Experimentation; COP
-
Studies on the gas circuit of a diffusion absor...
- Auteurs : MAIYA M. P.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
An experimental investigation of bubble pump pe...
- Auteurs : KOYFMAN A., JELINEK M., LEVY A., et al.
- Date : 10/2003
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 23 - n. 15
Voir la fiche
-
Experimental study of steam absorption enhancem...
- Auteurs : RIE D. H., KASHIWAGI T.
- Date : 11/1991
- Langues : Anglais
- Source : JSME int. J., Ser. II - vol. 34 - n. 4
Voir la fiche
-
The formation of non-condensable gases in ammon...
- Auteurs : MOSER H., ZOTTER G., KOTENKO O., et al.
- Date : 14/04/2011
- Langues : Anglais
- Source : 4th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 14-16, 2011.
- Formats : PDF
Voir la fiche
-
Performance characterization of a bubble pump f...
- Auteurs : AMAN J., HENSHAW P., TING D. S. K.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche