Influence de la non uniformité de la chaleur et de la source de contamination sur la performance de trois systèmes de distribution d'air de pièce.
The influence of heat and contaminant source nonuniformity on the performance of three different room air distribution methods.
Auteurs : HAGSTRÖM K. H., ZHIVOV A. M., SIRÉN K., et al.
Résumé
The heat and contaminant source nonuniformity and source location were found to have a major influence on the efficiencies of the room air distribution methods studied. For example, the occupied zone nonuniformity was fourfold at highest compared to the cases with a uniform source. Analysis of the data shows that with zonal room air distribution methods, both vertical and horizontal zoning are created when the sources are not uniform.
Détails
- Titre original : The influence of heat and contaminant source nonuniformity on the performance of three different room air distribution methods.
- Identifiant de la fiche : 2001-1978
- Langues : Anglais
- Source : ASHRAE Transactions. 1999 Annual Meeting, Seattle, Washington + CD-ROM.
- Date d'édition : 1999
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (57)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Autres équipements de conditionnement d'air
- Mots-clés : Contamination; Mesure; Température; Diffuseur d'air; Conditionnement d'air
-
Terminal form and application choice of cold ai...
- Auteurs : LI L., ZHANG J.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Temperature and velocity measurements on a diff...
- Auteurs : LINDEN E., CEHLIN M., SANDBERG M.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
Detailed measurements of airflow characteristic...
- Auteurs : CHUAH Y. K., HU S. C., BARBER J. M.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
Experimental study of vortex diffusers.
- Auteurs : SHAKERIN S., MILLER P. L.
- Date : 23/06/1996
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Experimental validation of jet formulae for air...
- Auteurs : SREBRIC J., LIU J., CHEN Q.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche