Document IIF
Intégration des systèmes frigorifiques au CO2 et des systèmes de trigénération afin de réaliser des économies d'énergie et d'émissions de gaz à effet de serre dans les supermarchés.
Integration of CO2 refrigeration and trigeneration systems for energy and GHG emission savings in supermarkets.
Auteurs : SUAMIR I., TASSOU S. A., MARRIOTT D.
Type d'article : Article, Article de la RIF
Résumé
The environmental impact of supermarkets is significant not only because of the indirect effect from CO2 emissions at the power stations but also due to the direct effect arising from refrigerant leakage to the atmosphere. One approach through which the overall energy efficiency can be increased and the environmental impacts reduced, is through the integration of CO2 refrigeration and trigeneration systems where the refrigeration generated by the trigeneration system is used to condense the CO2 refrigerant in a cascade arrangement. This paper reports on experimental and theoretical investigations of such a system and its potential application in a supermarket. The results show that the system can offer energy savings of 30%, greenhouse gas emission savings of 43% and a payback period of just over 3 years compared to conventional systems.
Documents disponibles
Format PDF
Pages : 407-417
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Integration of CO2 refrigeration and trigeneration systems for energy and GHG emission savings in supermarkets.
- Identifiant de la fiche : 30003296
- Langues : Anglais
- Sujet : Environnement
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 2
- Date d'édition : 03/2012
Liens
Voir d'autres articles du même numéro (22)
Voir la source
Indexation
-
Environmental assessment of biogas co- or trige...
- Auteurs : CHEVALIER C., MEUNIER F.
- Date : 12/2005
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 25 - n. 17-18
Voir la fiche
-
Energy and environmental comparison of commerci...
- Auteurs : GULLO P., CORTELLA G., POLZOT A.
- Date : 07/04/2016
- Langues : Anglais
- Source : 4th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Auckland, New Zealand, April 7-9, 2016.
- Formats : PDF
Voir la fiche
-
The evolution of CO2 refrigeration from trial t...
- Auteurs : CAMPBELL A., PEARSON A.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Energy and environmental performance assessment...
- Auteurs : GULLO P., ELMEGAARD B., CORTELLA G.
- Date : 04/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 64
- Formats : PDF
Voir la fiche
-
Refrigerant choice: new report reveals eco-effi...
- Auteurs : EPEE (European Partnership for Energy and the Environment)
- Date : 09/2010
- Langues : Anglais
- Source : www.epeeglobal.org - 5 p.; fig.; tabl.
Voir la fiche