Introduction du tube vortex annulaire et comparaison expérimentale avec un tube vortex de Ranque-Hilsch.

Introduction of annular vortex tube and experimental comparison with Ranque-Hilsch vortex tube.

Auteurs : SADI M., FARZANEH GORD M.

Type d'article : Article, Article de la RIF

Résumé

In order to enhance the Ranque–Hilsch Vortex Tube (RHVT) performance, an improved design of a Vortex Tube (VT) is introduced here. The new design of the VT which called Annular Vortex Tube (AVT) is experimentally tested and compared with a similar design RHVT. The hot stream, after passing the hot conical valve, redirected along the outer wall of hot tube in the AVT. This increases heat lost from outer wall of the hot tube. Results show that AVT has higher thermal separation performance comparing to RHVT. For optimum cold mass fraction, AVT improves cooling efficiency about 24% comparing to RHVT. The conical valve angle has also no effect on thermal performance of AVT. For AVT, three vortex generators are tested with different nozzle areas. All vortex generators have the same coefficient of performance in heating while vortex generator with higher nozzle area ratio represents better cooling efficiency among the others.

Documents disponibles

Format PDF

Pages : 142-151

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Introduction of annular vortex tube and experimental comparison with Ranque-Hilsch vortex tube.
  • Identifiant de la fiche : 30012279
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 46
  • Date d'édition : 10/2014

Liens


Voir d'autres articles du même numéro (21)
Voir la source