L'effet des tubes à rainures intérieures sur la performance du transfert de chaleur des échangeurs de chaleur refroidis à l'air pour un système à pompe à chaleur au CO2.
The effect of inner grooved tubes on the heat transfer performance of air-cooled heat exchangers for CO2 heat pump system.
Numéro : pap. 2347
Auteurs : KAJI R., YOSHIOKA S., FUJINO H.
Résumé
In the CO2 heat pump system, polyalkylene glycol (PAG) oil is commonly used for lubrication of the compressor, while it is reported that the PAG oil has influence on the heat transfer performance due to its immiscibility against CO2 within its working condition. Experimental work has been carried out to investigate the heat transfer performance of fin and tube heat exchangers using CO2 as a refrigerant with taking PAG oil into account. From previous study it was found that the heat transfer performance decreased significantly in both evaporator and gas-cooler conditions when oil was mixed. The present work presents experimental results on three types of air-cooled heat exchangers with smooth and inner grooved tubes. It was found that the deterioration ratio of heat transfer performance with oil was different depending on the inner surface geometry of the grooved tubes. To understand this, flow visualization inside these tubes has also been carried out through transparent section made of glass, which can withstand high pressure. It was confirmed that the oil behavior inside tubes was related to heat transfer performance. Heat transfer performance can be improved by using inner grooved tubes with the optimal pattern to remove oil away from inner surface. These tubes are effective to develop high performance heat exchangers for the CO2 heat pump system.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The effect of inner grooved tubes on the heat transfer performance of air-cooled heat exchangers for CO2 heat pump system.
- Identifiant de la fiche : 30006341
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (195)
Voir le compte rendu de la conférence
-
Effect of PAG oil circulation rate on the heat ...
- Auteurs : YOSHIOKA S., KIM H., KASAI K.
- Date : 20/05/2008
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
Voir la fiche
-
Shell and tube gas coolers for carbon dioxide h...
- Auteurs : ZILIO C., MANCIN S.
- Date : 17/06/2013
- Langues : Anglais
- Source : 4th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Comparative study of the use of compact heat ex...
- Auteurs : GARCÍA-CASCALES J. R., HIDALGO-MOMPEÁN F., RAMÍREZ-BASALO M. A., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Estudio de una bomba de calor aire/agua funcion...
- Auteurs : GARCÍA-CASCALES J. R., ILLÁN GÓMEZ F., HIDALGO-MOMPEÁN F., et al.
- Date : 03/05/2016
- Langues : Espagnol
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
Ground mass temperature analysis with the slink...
- Auteurs : ADAMOVSKÝ R., NEUBERGER P., MAŠEK L., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche