L'importance de la configuration du réservoir de liquide d'une pompe à chaleur sur l'impact lors d'un comportement transitoire.
The importance of heat pump liquid receiver configuration on the impact during transient behaviour.
Auteurs : PITARCH M., NAVARRO-PERIS E., GONZÁLVEZ-MACIÁ J., et al.
Résumé
The liquid receiver (LR) is a common accessory in heat pumps and refrigeration systems. Not only to accommodate excess of refrigerant to recovery from losses along time, but also to work with the optimum charge in systems where optimum refrigerant mass can vary at different operating conditions. Nevertheless, in the scientific literature, not many authors have paid attention to the influence of liquid receiver characteristics on the system performance and none of them has studied its influence during transient behavior due to changes in the operating conditions.
This work compares experimentally the effect of two different configurations designs of the inlet port for the liquid receiver. The differences are found in the shape of the inlet and outlet port inside the liquid receiver. The LR is installed in a heat pump for producing domestic hot water and working with propane, in such a systems the distribution of the charge is very important to
obtain great performance.
Results has shown that transient behavior differs highly depending on which LR configuration is used. For instance, the transient period last 35 minutes in one configuration, while in the other one takes less than 5 minutes.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The importance of heat pump liquid receiver configuration on the impact during transient behaviour.
- Identifiant de la fiche : 30017935
- Langues : Anglais
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Date d'édition : 03/05/2016
Liens
Voir d'autres communications du même compte rendu (132)
Voir le compte rendu de la conférence
-
Study of different subcooling control strategie...
- Auteurs : HERVÁS-BLASCO E., PITARCH M., NAVARRO-PERIS E., et al.
- Date : 04/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 88
- Formats : PDF
Voir la fiche
-
Transient modeling of a flash tank vapor inject...
- Auteurs : QIAO H., AUTE V., RADERMACHER R.
- Date : 01/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 49
- Formats : PDF
Voir la fiche
-
Transient modeling of a flash tank vapor inject...
- Auteurs : QIAO H., XU X., AUTE V., et al.
- Date : 01/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 49
- Formats : PDF
Voir la fiche
-
Sierra condensing unit uses a smaller refrigera...
- Date : 12/06/1995
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News - vol. 195 - n. 7
Voir la fiche
-
Liquid refrigerant pumping incorporating superh...
- Auteurs : TOMCZYK J. A.
- Date : 02/10/1996
- Langues : Anglais
- Source : New Developments in Refrigeration for Food Safety and Quality.
- Formats : PDF
Voir la fiche