Document IIF

Le système cryogénique pour les aimants supraconducteurs au NSRRC.

The cryogenic system for superconducting magnets at NSRRC.

Auteurs : LI H. C., HSIAO F. Z., CHANG S. H., et al.

Résumé

At the National Synchrotron Radiation Research Center (NSRRC) the second cryogenic plant with maximum cooling power of 450 W at 4.5 K or liquefaction rate of 115 l/hr was installed at the end of the year 2005. The mission of this cryogenic plant is supplying the cooling power to five superconducting magnets and being a backup of the first cryogenic plant, which supplies liquid helium to the superconducting cavity in the electron storage ring. This paper presents the function, design parameters and commission result of the second cryogenic plant. Results with the three in-operation superconducting magnets are shown also.

Documents disponibles

Format PDF

Pages : 2006-3/ICEC I-A1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : The cryogenic system for superconducting magnets at NSRRC.
  • Identifiant de la fiche : 2008-1165
  • Langues : Anglais
  • Source : Multiconference CryoPrague 2006 (9th Cryogenics 2006, ICEC 21, ICMC'06)
  • Date d'édition : 17/07/2006

Liens


Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence