Document IIF
Les caractéristiques en terme de performance d'un réfrigérateur à refroidissement direct utilisant un mélange de R-290 et de R-600a (55/45).
Performance characteristics of a small-capacity directly cooled refrigerator using R-290/R-600a (55/45).
Résumé
In this study, the performance of a small-capacity directly cooled refrigerator was evaluated by using the mixture of R-290 and R-600a with mass fraction of 55/45 as an alternative to R-134a. The compressor displacement volume of the alternative system with R-290/R-600a (55/45) was modified from that of the original system with R-134a to match the refrigeration capacity. Both systems with R-290/R-600a (55/45) and R-134a were tested, and then optimized by varying the refrigerant charge and capillary tube length under experimental conditions for both the pull-down test and the power consumption test. The refrigerant charge of the optimized R-290/R-600a system was approximately 50% of that of the optimized R-134a system. The capillary tube lengths for each evaporator in the optimized R-290/R-600a system were 500 mm longer than those in the optimized R-134a system. The power consumption of the optimized R-134a system was 12.3% higher than that of the optimized R-290/R-600a system. The cooling speed of the optimized R-290/R-600a (55/45) system at the in-case setting temperature of -15°C was improved by 28.8% over that of the optimized R-134a system.
Documents disponibles
Format PDF
Pages : 734-741
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance characteristics of a small-capacity directly cooled refrigerator using R-290/R-600a (55/45).
- Identifiant de la fiche : 2008-1653
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 4
- Date d'édition : 06/2008
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Experimental investigation of R290/R600a mixtur...
- Auteurs : MOHANRAJ M., JAYARAJ S., MURALEEDHARAN C., et al.
- Date : 05/2009
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 48 - n. 5
Voir la fiche
-
Comparative performance analysis of HFO1234ze/H...
- Auteurs : APREA C., GRECO A., MAIORINO A.
- Date : 10/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Formats : PDF
Voir la fiche
-
Le mélange de Dortmund dans le massif du Erz : ...
- Auteurs : MIRAU A.
- Date : 1993
- Langues : Allemand
- Source : Mondialisation et Energie - vol. 45 - n. 5
Voir la fiche
-
A review on domestic refrigerator using hydroca...
- Auteurs : KHANSAHEB S., KAPADIA R. G.
- Date : 05/2015
- Langues : Anglais
- Source : International Journal of Innovative Research in Science, Engineering and Technology (IJIRSET) - vol. 4, spec. issue 6
Voir la fiche
-
Improved energy efficiency for CFC domestic ref...
- Auteurs : SEKHAR S. J., MOHAN LAL D., RENGANARAYANAN S.
- Date : 03/2004
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 43 - n. 3
Voir la fiche