MESURE DE L'ECOULEMENT DIPHASIQUE DE FRIGORIGENE AVEC LA TECHNIQUE DE SEPARATION DU LIQUIDE ET DE LA VAPEUR.
TWO-PHASE REFRIGERANT FLOW MEASUREMENT WITH LIQUID AND VAPOUR SEPARATION TECHNIQUE.
Auteurs : MEI V. C.
Résumé
LES TECHNIQUES TRADITIONNELLES DE MESURE DE L'ECOULEMENT DIPHASIQUE SONT TROP CHERES OU D'UNE PRECISION INSUFFISANTE, ET PEUVENT MEME PRESENTER CES DEUX INCONVENIENTS A LA FOIS. DANS CE RAPPORT, ON PRESENTE UNE MESURE PRECISE DANS LAQUELLE LE LIQUIDE ET LA VAPEUR SONT SEPARES, ET ON MESURE LE DEBIT D'ECOULEMENT DE CHAQUE PHASE A L'AIDE DE DEBITMETRES HABITUELS. ON A CONSTRUIT UN SEPARATEUR DE GOUTTES A COUT PEU ELEVE ET A FAIBLE PERTE DE PRESSION ET ON L'A ESSAYE SUR UNE POMPE A CHALEUR A DEUX BLOCS. LES RESULTATS REVELENT QUE LE SEPARATEUR A FONCTIONNE COMME ON L'ESCOMPTAIT, EN SEPARANT LES DEUX PHASES DE L'ECOULEMENT DE FRIGORIGENE POUR UNE QUALITE DE VAPEURDE 6,1 A 14,7 %, AVEC UNE CHUTE DE PRESSION DU FRIGORIGENE ALLANT DE 14 A 35 KILOPASCALS, DANS LA PLUPART DES ESSAIS.
Détails
- Titre original : TWO-PHASE REFRIGERANT FLOW MEASUREMENT WITH LIQUID AND VAPOUR SEPARATION TECHNIQUE.
- Identifiant de la fiche : 1989-2210
- Langues : Anglais
- Date d'édition : 1988
- Source : Source : ASHRAE Trans.
vol. 94; n. 2; 238-243; 2 fig.; 1 tabl.; 8 ref.; discuss. - Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Indexation
-
Pressure drop prediction in two-phase flow of r...
- Auteurs : PALIWODA A.
- Date : 10/09/1996
- Langues : Anglais
- Source : Research, design and construction of refrigeration and air conditioning equipments in Eastern European countries.
- Formats : PDF
Voir la fiche
-
Study of two-phase flow in hairpins by means of...
- Auteurs : DE KERPEL K., AMEEL B., CANIÈRE H., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Visualization and two-phase pressure gradient i...
- Auteurs : PADILLA M., REVELLIN R., HABERSCHILL P., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Pressure drop of two-phase flow through horizon...
- Auteurs : ESKIN N., DENIZ E.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental results for HFO-1234yf visualizati...
- Auteurs : PADILLA M., REVELLIN R., HABERSCHILL P., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche