Méthode d'essai alternative pour l'évaluation de la performance énergétique des appareils frigorifiques domestiques sans formation de givre.

Alternative test method to assess the energy performance of frost-free refrigerating appliances.

Auteurs : HERMES C. J. L., MELO C., KNABBEN F. T.

Type d'article : Article

Résumé

This paper outlines an alternative test method to evaluate the energy consumption of frost-free refrigerators and freezers for residential applications. While the standardized methods require the refrigerating appliance to be kept running according to its onboard control system, which usually drives the refrigerator through an on-off cycling pattern, the proposed approach assesses the refrigerator energy performance in the steady-state regime, being therefore much faster and more reliable. In this procedure, the cooling capacity is matched to the cooling loads by PID-controlled electrical heaters installed within the refrigerated compartments, so that the compartment temperatures are kept at the desired standardized levels. Comparisons between the experimental results obtained using the steady-state energy test and the standardized procedures showed that the former follows closely the trends observed for the latter.

Détails

  • Titre original : Alternative test method to assess the energy performance of frost-free refrigerating appliances.
  • Identifiant de la fiche : 30006118
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 50 - n. 1
  • Date d'édition : 01/2013
  • DOI : http://dx.doi.org/10.1016/j.applthermaleng.2012.07.035

Liens


Voir d'autres articles du même numéro (64)
Voir la source