Document IIF
Meubles de vente à portes vitrées de faible coût et de haute efficacité fonctionnant au dioxyde de carbone transcritique.
High-efficiency, low-cost glass door merchandisers using transcritical carbon dioxide.
Numéro : pap. n. 305
Auteurs : PADILLA-FUENTES Y., HRNJAK P., ELBEL S.
Résumé
Glass door merchandisers are used in grocery and convenience stores to display chilled beverages or refrigerated foods. Among other possible choices for this application, carbon dioxide (R744, CO2) is seen as a promising low global warming potential (GWP) refrigerant alternative that is non-flammable and non-toxic. This study demonstrates that it is possible to design high-performance transcritical R744 glass door merchandiser systems that deliver cooling capacities and energy efficiencies that are comparable to results obtained with an R134a baseline system. In the present case, pull down time of the improved R744 system was slightly lower (97%), while energy efficiency was almost equal (103%) for tests conducted at an elevated ambient temperature of 32°C and 65% relative humidity. The most important observation is that these promising system results were obtained with low-cost technology, which was very comparable to what was used in the R134a system.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : High-efficiency, low-cost glass door merchandisers using transcritical carbon dioxide.
- Identifiant de la fiche : 30016150
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0305
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
CO2 - Mots-clés : R134a; Verre; Conception; R744; Porte; Efficacité énergétique; Frigorigène; CO2
-
Successful conversion and validation of glass d...
- Auteurs : ELBEL S., PADILLA-FUENTES Y., BOWERS C., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Assessment of energy efficiency and operating p...
- Auteurs : HUDJETZ S., KOHLER P., BECKER M.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
The advantages of natural working fluids.
- Auteurs : HAFNER A.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Development of a compressor control logic based...
- Auteurs : HSIEH C. H., CHEN G. W., CHANG Y. M., LI Y. M., YU P. Y.
- Date : 11/06/2024
- Langues : Anglais
- Source : 8th IIR International Conference on Sustainability and the Cold Chain. Proceedings: June 9-11 2024
- Formats : PDF
Voir la fiche
-
System efficiency for natural refrigerants.
- Auteurs : MIKHAILOV A., MATTHIESEN H. O.
- Date : 08/2013
- Langues : Anglais
- Source : ASHRAE Journal - vol. 55 - n. 8
Voir la fiche