Document IIF
Conversion réussie et validation de meubles frigorifiques de vente avec porte en verre utilisant le R744 transcritique.
Successful conversion and validation of glass door merchandisers using transcritical R744.
Numéro : pap. ID44
Auteurs : ELBEL S., PADILLA-FUENTES Y., BOWERS C., et al.
Résumé
Glass door merchandisers are used in grocery and convenience stores to display chilled beverages or refrigerated foods. Among other possible choices for this application, carbon dioxide (R744, CO2) is seen as a promising low global warming potential (GWP) refrigerant alternative that is non-flammable and nontoxic. This study demonstrates that it is possible to design high-performance transcritical R744 glass door merchandiser systems that deliver cooling capacities and energy efficiencies that are comparable to results obtained with an R134a baseline system. In the present case, pull down time of the improved R744 system was slightly lower (97%), while energy efficiency was almost equal (103%) for tests conducted at an elevated ambient temperature of 32°C and 65% relative humidity. The most important observation is that these promising system results were obtained with low-cost technology, which was very comparable to what was used in the R134a system.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Successful conversion and validation of glass door merchandisers using transcritical R744.
- Identifiant de la fiche : 30013164
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Date d'édition : 02/08/2014
Liens
Voir d'autres communications du même compte rendu (119)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : Application commerciale; Verre; Meuble de vente; Conception; R744; Porte; Performance; Experimentation; Cycle transcritique; CO2
-
Performance of an integral display cabinet work...
- Auteurs : ABDALLAH R. ben, LEDUCQ D., HOANG H. M., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
The transcritical CO2 cycle in light commercial...
- Auteurs : VEJE C., SÜSS J.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Simulations and field tests of a CO2 refrigerat...
- Auteurs : CORTELLA G., D'AGARO P., COPPOLA M. A.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Design and analysis of a transcritical R-744 bo...
- Auteurs : CECCHINATO L., CORRADI M., FORNASIERI E., et al.
- Date : 08/06/2007
- Langues : Anglais
- Source : Technological innovations in air-conditioning and refrigeration industry + CD-ROM.
Voir la fiche
-
Development of a transcritical R-744 bottle coo...
- Auteurs : CECCHINATO L., CORRADI M., FORNASIERI E., et al.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche