Document IIF
Conversion réussie et validation de meubles frigorifiques de vente avec porte en verre utilisant le R744 transcritique.
Successful conversion and validation of glass door merchandisers using transcritical R744.
Numéro : pap. ID44
Auteurs : ELBEL S., PADILLA-FUENTES Y., BOWERS C., et al.
Résumé
Glass door merchandisers are used in grocery and convenience stores to display chilled beverages or refrigerated foods. Among other possible choices for this application, carbon dioxide (R744, CO2) is seen as a promising low global warming potential (GWP) refrigerant alternative that is non-flammable and nontoxic. This study demonstrates that it is possible to design high-performance transcritical R744 glass door merchandiser systems that deliver cooling capacities and energy efficiencies that are comparable to results obtained with an R134a baseline system. In the present case, pull down time of the improved R744 system was slightly lower (97%), while energy efficiency was almost equal (103%) for tests conducted at an elevated ambient temperature of 32°C and 65% relative humidity. The most important observation is that these promising system results were obtained with low-cost technology, which was very comparable to what was used in the R134a system.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Successful conversion and validation of glass door merchandisers using transcritical R744.
- Identifiant de la fiche : 30013164
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Date d'édition : 02/08/2014
Liens
Voir d'autres communications du même compte rendu (119)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : Application commerciale; Verre; Meuble de vente; Conception; R744; Porte; Performance; Experimentation; Cycle transcritique; CO2
-
A study on carbon dioxide cycle architectures f...
- Auteurs : MONTAGNER G. P., MELO C.
- Date : 06/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 42
- Formats : PDF
Voir la fiche
-
A study on CO2 cycle architectures for light co...
- Auteurs : MONTAGNER G. P., MELO C.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche
-
Development of a R744 low side variable speed s...
- Auteurs : TANG Y. J., LIU Y. G.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 21st International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Performance of an integral display cabinet work...
- Auteurs : ABDALLAH R. ben, LEDUCQ D., HOANG H. M., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
Design and experimental analysis of a carbon di...
- Auteurs : BERNABEI M., CECCHINATO L., CHIARELLO M., et al.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF