Modèle de calcul rapide des propriétés thermodynamiques et de transport de CO2 dans la région de pression surcritique.

[In Chinese. / En chinois.]

Auteurs : LONG Q., ZENG W., GU B., et al.

Type d'article : Article

Résumé

A uniform fast calculation model for CO2 thermodynamic and transport properties in overcritical pressure region was proposed. The calculation stability and fast calculation speed for the properties of CO2 can be ensured due to its explicit expression and no need of iteration. With the source date from REFPROP7, the thermodynamic properties of CO2 were simulated in the range from the critical point to 22.2 MPa and from T(pc)-100 K to T(pc) and from T(pc) to T(pc)+200 K. The comparison result shows that the calculation speed of this fast calculation model is two to four orders faster than that of REFPROP7. Moreover, the total mean relative deviation and maximum relative deviation of all the fast calculation models is less than 0.5898 and 13.30% respectively.

Documents disponibles

Format PDF

Pages : 30-35

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : [In Chinese. / En chinois.]
  • Identifiant de la fiche : 2009-1018
  • Langues : Chinois
  • Source : Journal of Refrigeration - vol. 29 - n. 124