Document IIF
Modèle de consommation d'énergie d'un conditionneur d'air intégré avec un thermosiphon dans une antenne-relais pour téléphones portables.
Energy consumption model of integrated air conditioner with thermosyphon in mobile phone base station.
Résumé
Data centers and mobile phone base stations (MBS) are consuming more and more energy due to the development of the information communication technology (ICT) industry. The integrated air conditioner with thermosyphon (IACT) was proposed as an efficient cooling device for these spaces, combining vapor compression (VC) refrigeration with a thermosyphon (TS). In this paper, a model to simulate the annual energy consumption of IACT is built and compared with the traditional air conditioner (TAC) in four standard MBSs located in the typical climate zones of China. The results show that the IACT saves 19.1%–28.2% more energy than the TAC, and in hotter regions has a larger energy saving amount but a smaller energy saving rate (ESR). The TS mode works effectively when the mean monthly temperature is 5.4°C-24.5°C. The monthly ESR of IACT in the MBSs of Beijing and Guangzhou is 12.2%–48.6% and 12.1%–45.2% respectively.
Documents disponibles
Format PDF
Pages : 1-10
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy consumption model of integrated air conditioner with thermosyphon in mobile phone base station.
- Identifiant de la fiche : 30010709
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Date d'édition : 04/2014
Liens
Voir d'autres articles du même numéro (41)
Voir la source
-
Development of an integrated air conditioner wi...
- Auteurs : HAN L., SHI W., WANG B., et al.
- Date : 01/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
Voir la fiche
-
Energy-saving potential study on telecommunicat...
- Auteurs : ZHOU F., CHEN J., MA G. Y., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
DEVELOPMENT OF LOW-ENERGY AIR CONDITIONING SYST...
- Auteurs : PRUDHOE R. K.
- Date : 1981
- Langues : Anglais
- Source : Aust. Refrig. Air Cond. Heat. - vol. 35 - n. 4
Voir la fiche
-
Étude des systèmes de refroidissement à air ext...
- Auteurs : UDAGAWA Y., SEKIGUCHI K., YANAGI M., et al.
- Date : 12/2012
- Langues : Japonais
- Source : Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 189
Voir la fiche
-
Optimisation de la performance de l'enveloppe e...
- Auteurs : TU R., LI Z., LIU X., et al.
- Date : 12/2011
- Langues : Chinois
- Source : HV & AC - vol. 41 - n. 258
- Formats : PDF