Summary
Data centers and mobile phone base stations (MBS) are consuming more and more energy due to the development of the information communication technology (ICT) industry. The integrated air conditioner with thermosyphon (IACT) was proposed as an efficient cooling device for these spaces, combining vapor compression (VC) refrigeration with a thermosyphon (TS). In this paper, a model to simulate the annual energy consumption of IACT is built and compared with the traditional air conditioner (TAC) in four standard MBSs located in the typical climate zones of China. The results show that the IACT saves 19.1%–28.2% more energy than the TAC, and in hotter regions has a larger energy saving amount but a smaller energy saving rate (ESR). The TS mode works effectively when the mean monthly temperature is 5.4°C-24.5°C. The monthly ESR of IACT in the MBSs of Beijing and Guangzhou is 12.2%–48.6% and 12.1%–45.2% respectively.
Available documents
Format PDF
Pages: 1-10
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Energy consumption model of integrated air conditioner with thermosyphon in mobile phone base station.
- Record ID : 30010709
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Publication date: 2014/04
Links
See other articles in this issue (41)
See the source
Indexing
-
Development of an integrated air conditioner wi...
- Author(s) : HAN L., SHI W., WANG B., et al.
- Date : 2013/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
View record
-
Energy-saving potential study on telecommunicat...
- Author(s) : ZHOU F., CHEN J., MA G. Y., et al.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Study on outdoor air-cooling systems for data c...
- Author(s) : UDAGAWA Y., SEKIGUCHI K., YANAGI M., et al.
- Date : 2012/12
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 189
View record
-
DEVELOPMENT OF LOW-ENERGY AIR CONDITIONING SYST...
- Author(s) : PRUDHOE R. K.
- Date : 1981
- Languages : English
- Source: Aust. Refrig. Air Cond. Heat. - vol. 35 - n. 4
View record
-
Performance optimization of the envelope and ai...
- Author(s) : TU R., LI Z., LIU X., et al.
- Date : 2011/12
- Languages : Chinese
- Source: HV & AC - vol. 41 - n. 258
- Formats : PDF
View record