Modèle de prévision mécaniste des taux de fuite à travers des fissures.
Mechanistic prediction model for leakage rates through cracks.
Auteurs : FRIEDEL L., WESTPHAL F.
Type d'article : Article
Résumé
A mechanistic model for prediction of leakage rates through small, slit-shaped, subcritical through-wall cracks is proposed. It encompasses the whole range of possible upstream fluid states from subcooled liquid via two-phase mixture to superheated vapor. The model is, essentially, based on a semi-empirical relationship for the transient pressure drop across the crack and the concept of Pana for a critical mass flux calculation. The leakage rate predictions are checked against our own and literature data obtained in experiments with subcritical and critical flow of initially subcooled nonflashing and flashing refrigerants and water through real and model cracks over a wide parameter ranges. The overall predictive accuracy is in the range of the measuring accuracy of the experimental results and hence sufficient for technical purposes.
Détails
- Titre original : Mechanistic prediction model for leakage rates through cracks.
- Identifiant de la fiche : 30009146
- Langues : Anglais
- Source : Experimental Thermal and Fluid Science - vol. 3 - n. 5
- Date d'édition : 09/1990
- DOI : http://dx.doi.org/10.1016/0894-1777(90)90067-H
Liens
Voir la source
Indexation
- Thèmes : Confinement, réduction de la charge en frigorigène
- Mots-clés : Écoulement diphasique; Rate; Prévision; Modèle; Fuite; Frigorigène; Chute de pression
-
A generalized analytic method for predicting re...
- Auteurs : HONG S. B., YOO J. W., KIM M. S.
- Date : 23/04/2017
- Langues : Anglais
- Source : 5th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants.
- Formats : PDF
Voir la fiche
-
Estimation of refrigerant charge inventory for ...
- Auteurs : PULINKUZHI V., THAKOR V., DATTA S. P., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Guide to Good Leak Testing.
- Auteurs : Institute of Refrigeration, Carbon Trust
- Date : 01/2009
- Langues : Anglais
Voir la fiche
-
Two-phase pressure drop with non uniform distri...
- Auteurs : LÓPEZ BELCHÍ A., VERA-GARCÍA F., GARCÍA-CASCALES J. R., et al.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Prediction model of two-phase flow distribution...
- Auteurs : ONAKA Y., ADACHI R., KISHIDA N., MATSUMOTO T.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche