Modélisation par simulation dynamique et commande d’une unité de traitement d’air multifonction à détente directe assistée d’un déshydratant.
Dynamic simulation modeling and control of a desiccant assisted direct-expansion multi-functional air handling unit.
Résumé
Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HVAC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature-humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Gratuit
Détails
- Titre original : Dynamic simulation modeling and control of a desiccant assisted direct-expansion multi-functional air handling unit.
- Identifiant de la fiche : 30033035
- Langues : Anglais
- Sujet : Technologie
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 17/07/2024
Liens
Voir d'autres communications du même compte rendu (187)
Voir le compte rendu de la conférence
Indexation
-
Careful attention to HVAC systems and improveme...
- Auteurs : GONG Y., GAO W.
- Date : 1997
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
Voir la fiche
-
The philosophy behind ventilation: past, presen...
- Auteurs : FANGER O.
- Date : 07/1996
- Langues : Anglais
Voir la fiche
-
Temperature and humidity: important factors for...
- Auteurs : FANG L., CLAUSEN G., FANGER P. O.
- Date : 24/06/2000
- Langues : Anglais
- Source : ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.
Voir la fiche
-
RANS and LES models of a lobed jet flow integra...
- Auteurs : BODE F., NASTASE I., MESLEM A., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Zulässige Empfundene Luftqualität in Innenräumen.
- Auteurs : DKV, SPIESS T., FITZNER K.
- Date : 19/11/1997
- Langues : Allemand
- Source : DKV-Tagungsbericht 24. 1997, Hamburg.
Voir la fiche