Nouvelle technique permettant d'évaluer les fuites à partir des gaines dans les logements.
The nulling test: a new measurement technique for estimating duct leakage in residential homes.
Auteurs : FRANCISCO P. W., PALMITER L. S.
Résumé
This collection of 107 papers presented at the ASHRAE 2001 Winter Meeting, held in Atlanta, Georgia, January 27-31, include the complete collection of symposium and technical papers as well as discussion questions and answers for every paper. Topics: case studies and modeling for heating systems with special emphasis on radiant panel systems; central energy plant kW per ton and demand controls; innovative materials and building envelope systems; absorption/sorption heat pumps and refrigeration systems; analysis tools for the design of low energy cooling systems; thermal-energy storage systems aging gracefully; integration of dedicated outside air dehumidification systems and terminal sensible cooling/heating; pumping design and performance modeling of geothermal heat pump systems; thermoeconomics and second law analysis of HVAC&R systems; characterizing the performance of non-simple fenestrations; smoke management research and case studies of large spaces; effects of international building code 2000 on seismic design for HVAC; modelling and measurement of VOC emissions from building materials; recent results from fault detection and diagnostic research; combustion turbine inlet cooling; advances in thermal and fluid flow characteristics of HVAC and refrigeration processes.
Détails
- Titre original : The nulling test: a new measurement technique for estimating duct leakage in residential homes.
- Identifiant de la fiche : 2002-0951
- Langues : Anglais
- Source : ASHRAE Transactions. 2001 Winter Meeting, Atlanta, GA. Volume 107, part 1 + CD-ROM.
- Date d'édition : 2001
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (60)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Autres équipements de conditionnement d'air
- Mots-clés : Mesure; Air; Procédé; Gaine; Fuite; Conditionnement d'air; Distribution d'air
-
Tech page: air-side diagnostics.
- Auteurs : ROTHACKER D. E.
- Date : 22/04/2002
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News/achrnews.com - 4 p.
Voir la fiche
-
Field and laboratory evaluation of a new rampin...
- Auteurs : WALKER I. S., DICKERHOFF D.
- Date : 21/06/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Annual Meeting, Salt Lake City, UT. Volume 114, part 2 + CD-ROM.
Voir la fiche
-
Laboratory and field testing of an aerosol-base...
- Auteurs : CARRIÉ F. R., LEVINSON R. M., XU T. T., et al.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche
-
Tracer-gas techniques for measuring airflow in ...
- Auteurs : RIFFAT S. B., CHEONG K. W.
- Date : 08/1995
- Langues : Anglais
- Source : Int. J. Energy Res. - vol. 19 - n. 6
Voir la fiche
-
L'étanchéité des réseaux aérauliques en cause.
- Date : 03/1999
- Langues : Français
- Source : Chaud Froid Plomb. - n. 611
Voir la fiche