Document IIF
Optimisation énergétique d’un réfrigérateur domestique contrôlé par un système de logique floue utilisant le statut de la porte.
Energy optimization of a domestic refrigerator controlled by a fuzzy logic system using the status of the door.
Auteurs : BELMAN-FLORES J. M., LEDESMA S., RODRIGUEZ-VALDERRAMA D. A., et al.
Type d'article : Article, Article de la RIF
Résumé
This paper proposes a novel fuzzy logic control system for a domestic refrigerator taking into consider- ation the status of the door. The goal of this system is to keep the temperature of the fresh food com- partment as close as possible to the set point while saving energy. The fuzzy logic system was set up to control the speed of the compressor. The set of inference rules in this study incorporated the frequency and duration of the door opening. These rules try reducing the compressor speed at a minimum value, and therefore, reducing the number of times the compressor is turned offwhen the door is open. To compare and evaluate the control systems, several tests with different configuration and rules were per- formed. Each test ran for seventeen hours, during this time the test included three periods when the door was opened and closed several times. It was concluded that the electric current when the compres- sor starts was reduced and produced an overall energy saving of 3%. Thus, it is evident that the more information is incorporated into a fuzzy logic system, the more energy savings can be obtained.
Documents disponibles
Format PDF
Pages : 1-8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy optimization of a domestic refrigerator controlled by a fuzzy logic system using the status of the door.
- Identifiant de la fiche : 30026558
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Date d'édition : 08/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.04.025
Liens
Voir d'autres articles du même numéro (50)
Voir la source
Indexation
-
Implementation of fuzzy control in a domestic r...
- Auteurs : RODRIGUEZ-VALDERRAMA D. A., BELMAN-FLORES J. M., HERNANDEZ-FUSILIER D., PARDO-CELY D. M., GOMEZ-MARTINEZ M. A., MENDEZ-DIAZ S.
- Date : 05/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 149
- Formats : PDF
Voir la fiche
-
EFFECTS OF AMBIENT TEMPERATURE, AMBIENT HUMIDIT...
- Auteurs : ALISSI M. S., RAMADHYANI S., SCHOENHALS R. J.
- Date : 1988
- Langues : Anglais
Voir la fiche
-
Investigations of the EPA Refrigerator Analysis...
- Auteurs : HAIDER I., LAVANNIS M. K., RADERMACHER R.
- Date : 1997
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Refrigerator energy use in the laboratory and i...
- Auteurs : MEIER A.
- Date : 08/1995
- Langues : Anglais
- Source : Energy Build. - vol. 22 - n. 13
Voir la fiche
-
Performance comparison with effect of door open...
- Auteurs : LIU D. Y., CHANG W. R., LIN J. Y.
- Date : 10/2004
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 24 - n. 14-15