Document IIF
Optimisations à partir de la modélisation de climatiseurs de toit monoblocs utilisant des frigorigènes à faible potentiel de réchauffement planétaire.
Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants.
Auteurs : SHEN B., ABDELAZIZ O., SHRESTHA S., et al.
Type d'article : Article, Article de la RIF
Résumé
Based on laboratory investigations for R-22 and R-410A alternative low GWP refrigerants in two baseline rooftop air conditioners (RTU), the DOE/ORNL Heat Pump Design Model was used to model the two RTUs and the models were calibrated against the experimental data. We compared the compressor efficiencies and heat exchanger performances. An efficiency-based compressor mapping method was developed. Extensive model-based optimizations were conducted to provide a fair comparison between all the low GWP candidates by selecting optimal configurations. The results illustrate that all the R-22 low GWP refrigerants will lead to slightly lower COPs. ARM-20B appears to be the best R-22 replacement at normal conditions. At higher ambient temperatures, ARM-20A exhibits better performance. All R-410A low GWP candidates will result in similar or better efficiencies than R-410A. R-32 has the best COP while requiring the smallest compressor. R-452B uses the closest compressor displacement volume and achieves the same efficiency as R-410A.
Documents disponibles
Format PDF
Pages : 106-117
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants.
- Identifiant de la fiche : 30023885
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 87
- Date d'édition : 03/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.10.028
Liens
Voir d'autres articles du même numéro (14)
Voir la source
Indexation
-
Thèmes :
HFC;
Conditionnement d'air pour le confort;
Mélanges - Mots-clés : R410A; Toiture; Comparaison; Faible GWP; Conditionneur d'air; R22; Modèle; Frigorigène
-
A/C in high ambient temperatures. Comparisons o...
- Auteurs : LARMINAT P. de, WANG L.
- Date : 20/07/2017
- Langues : Anglais
- Source : 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF
Voir la fiche
-
Evaluation on the application of R-410A in resi...
- Auteurs : CHEN W., SPATZ M. W., YANA MOTTA S., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Replacements for R410A with GWPs less than 300.
- Auteurs : SCHULTZ K.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Experimental studying on low GWP refrigerant R4...
- Auteurs : LIN E., NIU Y., HUO H., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Noodzaak tot alternatieven voor R410A in comfor...
- Auteurs : DIJKSMA A.
- Date : 04/2016
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 109 - n. 4
Voir la fiche