Document IIF
Past versus state of the art – overcoming limitations of low fin tubes using high efficiency process boiling technology in mixed refrigerant pre-cooling trains.
Numéro : 84
Auteurs : RAMBURE N., RONGIER C., BUFFET A., SAAD L. R., GOURIOU J., DUARTE N., LANG T., HAJAL J. el
Résumé
Liquefied Natural Gas (LNG) production continues to expand worldwide, with a global liquefaction capacity approaching 495 million tons per year in 2024. As LNG grows in strategic importance for the global energy transition, the industry faces increasing pressure to improve thermodynamic
efficiency, reduce costs, and minimize greenhouse gas (GHG) emissions. Within this context, the C3/MRTM (Propane Pre-Cooling Mixed Refrigerant) liquefaction process, the most widely deployed LNG process globally, plays a critical role.
Traditional pre-cooling heat exchangers rely predominantly on Low-Fin tubes, a technology widely adopted over several decades. While robust and reliable, Low-Fin tubes impose important constraints on heat exchanger dimensions, propane inventory, installation complexity, and achievable temperature approaches. These limitations ultimately affect both CAPEX and OPEX, as well as the carbon footprint of LNG plants.
Recent advances in heat transfer research have enabled the development of dual enhanced nucleate boiling tube, known commercially as GEWA-PB. These tubes are jointly engineered by Technip Energies1 and Wieland Thermal Solutions2. With over 20 years of successful track record in LNG plants with more than 185 Mtpa of installed capacity. This technology is now considered the benchmark for high-efficiency boiling surfaces in LNG propane trains.
This article compares conventional Low-Fin tubes with GEWA-PB enhanced boiling technology, presents a case study of their implementation in a new 2x5 Mtpa LNG plant in the Middle East, and evaluates economic and environmental impacts. The objective is to demonstrate how enhanced boiling technology enables more compact, energy-efficient, and sustainable LNG facilities.
Documents disponibles
Format PDF
Pages : 13 p.
Disponible
Gratuit
Fichier PDF des diapositives de la présentation
Pages : 5 p.
Disponible
Gratuit
Détails
- Titre original : Past versus state of the art – overcoming limitations of low fin tubes using high efficiency process boiling technology in mixed refrigerant pre-cooling trains.
- Identifiant de la fiche : 30034697
- Langues : Anglais
- Sujet : Technologie
- Source : 21st International Conference & Exhibition on Liquefied Natural Gas (LNG2026)
- Date d'édition : 05/02/2026
Liens
Voir d'autres communications du même compte rendu (48)
Voir le compte rendu de la conférence
Indexation
-
Review of variable geometry air-to-refrigerant ...
- Auteurs : O'MALLEY B., AUTE V., BACELLAR D., RADERMACHER R.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Numerical model for water vapour condensation o...
- Auteurs : ZHUANG D., YANG Y., DING G., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
A review of the state of the art in modeling of...
- Auteurs : AUTE V.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Comparison on evaporation heat transfer between...
- Auteurs : NAKAMURA S., KONDOU C., TAKATA N., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
PROBLEM AND SOLUTION TO PLUGGING OF A FINNED TU...
- Auteurs : BRAUN R. H.
- Date : 1986
- Langues : Anglais
Voir la fiche