Résumé
Annual performance factor (APF) is employed to indicate the average annual energy consumption efficiency of air conditioners. A higher APF corresponds to better performance. The APF calculation method for packaged air conditioners is stipulated by Japanese Industrial Standards (JIS) B 8616:2006. For an inverter-driven compressor air conditioners, the CD value, which determines the degradation in energy efficiency, is set to zero when the minimum capacity of the test air conditioner is smaller than half its rated capacity, which is the case for almost all packaged air conditioners in the Japanese market. In order to evaluate whether the APF calculated using JIS B 8616:2006 corresponds to the actual annual energy consumption efficiency, a systematic investigation was conducted using four packaged air conditioners having rated cooling capacities of 7 kW each and two multi-type air conditioners having cooling capacities of 28 kW each: the air conditioners were produced by different manufacturers. Cooling performance was tested at rated capacity and half capacity, and tests were carried out under partial load conditions with load ratios ranging from 15 to 50%. Similarly, heating performance was tested under several temperature and load ratio conditions. The measured APF was compared with the value calculated according to JIS, and it was found that when the compressor works intermittently, the calculated APF differed greatly from the measured value, with the largest deviation being about 42%. On the basis of the experimental results, we propose a new rating method that involves changing the CD from zero to 0.25 in order to provide the actual operating performance, especially under low load ratio conditions. By using the proposed new rating method, the mean deviation between the calculated APF and the measured APF has been reduced to less than 3%.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Annual performance and performance rating of air conditioners.
- Identifiant de la fiche : 30005372
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Date d'édition : 07/06/2010
Liens
Voir d'autres communications du même compte rendu (107)
Voir le compte rendu de la conférence
-
Statistical analysis on design energy efficienc...
- Auteurs : XIAO Y., FU X., LIN Z., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
FACTORS INFLUENCING OVERALL BUILDING EFFICIENCY.
- Auteurs : JONES J. R., BOONYATIKARN S.
- Date : 1990
- Langues : Anglais
Voir la fiche
-
Tale of two low-energy designs: comparison of m...
- Auteurs : WALKER C. E., GLICKSMAN L. R., NORFORD L. K.
- Date : 27/01/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
Voir la fiche
-
Analytical modelling of an indirect evapo...
- Auteurs : RAMÍREZ R. J., ARRANZ C. G., OPOLOT M., LEE S., ZHAO C.
- Date : 26/06/2024
- Langues : Anglais
- Source : 12th CYTEF Congress - Ibero-American Congress of Refrigeration Science and Technology.
- Formats : PDF
Voir la fiche
-
Study on the smart operation approach of an air...
- Auteurs : YOON M. S., YOON W. S.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche