Performance expérimentale du R-1234yf et du R-1234ze comme frigorigènes de remplacement immédiat du R-134a dans les réfrigérateurs domestiques.
Experimental performance of R-1234yf and R-1234ze as drop-in replacements for R-134a in domestic refrigerators.
Numéro : pap. 2241
Auteurs : KARBER K. M., ABDELAZIZ O., VINEYARD E. A.
Résumé
Concerns about anthropogenic climate change have generated an interest in low global warming potential (GWP) refrigerants and have spawned policies and regulations that encourage the transition to low GWP refrigerants. Recent research has largely focused on hydrofluoroolefins (HFOs), including R-1234yf (GWP = 4) as a replacement for R-134a (GWP = 1430) in automotive air-conditioning applications. While R-1234yf and R-1234ze (GWP = 6) have been investigated theoretically as a replacements for R-134a in domestic refrigeration, there is a lack of experimental evidence. This paper gives experimental performance data for R-1234yf and R-1234ze as drop-in replacements for R134a in two household refrigerators – one baseline and one advanced technology. An experiment was conducted to evaluate and compare the performance of R-134a to R-1234yf and R-1234ze, using AHAM standard HRF-1 to evaluate energy consumption. These refrigerants were tested as drop-in replacements, with no performance enhancing modifications to the refrigerators. In Refrigerator 1 and 2, R-1234yf had 2.7% and 1.3% higher energy consumption than R-134a, respectively. This indicates that R-1234yf is a suitable drop-in replacement for R-134a in domestic refrigeration applications. In Refrigerator 1 and 2, R-1234ze had 16% and 5.4% lower energy consumption than R-134a, respectively. In order to replace R-134a with R-1234ze in domestic refrigerators the lower capacity would need to be addressed, thus R-1234ze might not be suitable for drop-in replacement.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental performance of R-1234yf and R-1234ze as drop-in replacements for R-134a in domestic refrigerators.
- Identifiant de la fiche : 30006502
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (195)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Applications domestiques (réfrigérateurs, congélateurs) - Mots-clés : R134a; R1234yf; Réfrigerateur domestique; R1234ze; Substitut; Performance; Experimentation
-
Theoretical analysis of low GWP mixture R600a/R...
- Auteurs : QIU J., ZHANG H., WANG Z., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Nature refrigerant: propane.
- Auteurs : JAMES R. W., MISSENDEN J. F.
- Date : 27/09/1993
- Langues : Anglais
- Source : Proceedings of the 1993 non-fluorocarbon insulation, refrigeration and air-conditioning technology workshop.
Voir la fiche
-
Le froid domestique après les CFC.
- Auteurs : BUCCIARELLI M.
- Date : 16/06/1995
- Langues : Italien
- Source : I nuovi refrigeranti ed il settore alimentare. Le ultime tecnologie e il futuro del freddo e del condizionamento. / The new refrigerants and the food industry.The future of refrigeration and air conditioning.
Voir la fiche
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Performance evaluation of HFO-1234yf as a subst...
- Auteurs : LEE J. S., LEE M. R., JEON S.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche