Performance thermique d’une pompe à chaleur géothermique utilisant les pieux de fondation à tubes en acier d’une maison.
Thermal performance of ground source heat pump using steel pipe pile for house.
Numéro : pap. n. 905
Auteurs : AOKI T., TAKEDA T., ISHIGURO S., et al.
Résumé
Nowadays, ground source heat pump (GSHP) are attracting attention as an energy saving technology in cooling and heating systems. The objective of this study is to evaluate the performance of a GSHP that uses the direct expansion method, in cooling and heating air conditioning applications. This pump utilizes the steel pipe foundation pile of the house to accommodate its heat exchanger. To achieve the same, 12 underground heat exchangers were inserted into the foundation piles. Experiments were conducted to study its performance in both cooling and heating operations, and the coefficient of performance (COP) was obtained by measuring the amount of heat transferred and the electricity consumption for running the GSHP. From the experimental result obtained, the COP was approximately 4.0 in the cooling operation and approximately 4.8 in the heating operation. Additionally, no performance deterioration was observed in the intermittent cooling or heating operation for 5 days.
Documents disponibles
Format PDF
Pages : 7
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Thermal performance of ground source heat pump using steel pipe pile for house.
- Identifiant de la fiche : 30026497
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0905
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
-
Análisis experimental de una bomba de calor geo...
- Auteurs : AIRA R., FERNÁNDEZ-SEARA J., FERNÁNDEZ CID D., et al.
- Date : 19/06/2018
- Langues : Espagnol
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
Performance of ground source heat pump that use...
- Auteurs : NISHIZAWA R., TAKEDA T., ISHIGURO S., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Long-term energy and exergy analysis of heat pu...
- Auteurs : HABIBI M., HAKKAKI-FARD A.
- Date : 04/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 100
- Formats : PDF
Voir la fiche
-
Thermal performance of underground heat exchang...
- Auteurs : OKAZAWA R., TAKEDA T., ISHIGURO S.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Comparison of the energy consumption of ground-...
- Auteurs : TAMMARO M., MONTAGUD C., CORBERÁN J. M., et al.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche