PERTES PAR CYCLAGE, GIVRAGE ET DEGIVRAGE, MESUREES DANS DES CONDITIONS REELLES D'UTILISATION, D'UNE POMPE A CHALEUR A SOURCE D'AIR A GRAND RENDEMENT.

FIELD-MEASURED CYCLING, FROSTING AND DEFROSTING LOSSES FOR A HIGH-EFFICIENCY AIR-SOURCE HEAT PUMP.

Résumé

UNE POMPE A CHALEUR AIR-AIR A ETE INSTALLEE DANS UNE MAISON INDIVIDUELLE INOCCUPEE ET A FONCTIONNE DANS UN ESSAI POUR DETERMINER LES PERTES DYNAMIQUES DE PUISSANCE ET DE RENDEMENT DUES AU CYCLAGE, AU GIVRAGE ET AU DEGIVRAGE. AU COURS DE LA SAISON DE CHAUFFAGE, LES PERTES PAR DEGIVRAGE ETAIENT RESPONSABLES DE 10,2 % DE LA CONSOMMATION D'ENERGIE TOTALE, LES PERTES PAR GIVRAGE DE 3,7 %, LES PERTES TRANSITOIRES PAR DEMARRAGE DE 8,5 % ET LA CONSOMMATION < PARASITE > PENDANT LES TEMPS D'ARRET DE 3,3 %. LA PERFORMANCE EN REGIME PERMANENT EN MODE DE REFROIDISSEMENT A ETE REDUITE PAR RAPPORT AUX INDICATIONS DU FABRICANT PAR SUITE SURTOUT D'UNE PETITE FUITE DE FRIGORIGENE. CEPENDANT ON A TROUVE QUE LES PERTES TRANSITOIRES AU DEMARRAGE REPRESENTAIENT 2,8 % DE LA CONSOMMATION TOTALE D'ENERGIE ET LA CONSOMMATION < PARASITE > PENDANT LES TEMPS D'ARRET 4,4 %.

Détails

  • Titre original : FIELD-MEASURED CYCLING, FROSTING AND DEFROSTING LOSSES FOR A HIGH-EFFICIENCY AIR-SOURCE HEAT PUMP.
  • Identifiant de la fiche : 1987-0288
  • Langues : Anglais
  • Date d'édition : 1985
  • Source : Source : ASHRAE Trans.
    vol. 91; n. 2B; 537-554; 11 fig.; 13 tabl.; 20 ref.; discuss.