Peut-on obtenir le confort thermique dans un bâtiment passif à faible consommation d'énergie ? Étude du confort thermique dans une salle de classe d'une région tropicale humide.
May we obtain thermal comfort with passive and low energy building? Study of thermal comfort in humid tropical classroom.
Numéro : pap. 955
Auteurs : KINDANGEN J.
Résumé
Thermal comfort is one of determinant factors in increasing concentration in teaching and learning process. This study has assessed the comfort level in classroom at the Engineering Faculty of Sam Ratulangi University Manado. The classroom was designed to operate as long as possible by using passive techniques and having Intensity of Consumption Energy at below of 70 kWh/m2/year. The study was conducted by spreading questionnaires to find out how the thermal comfort responses on several conditions, using ceiling fan or not, and by measuring air temperature, relative humidity and wind speed. We found that the noon and the afternoon is a critical time which tends to lower the comfort level. There is over 70% of respondents expressed discomfort at the noon and the afternoon without using ceiling fan. However, at the noon with quite high temperature, the effects of using ceiling fan are not able to increase significantly level of thermal comfort, but at the afternoon the use of fan was instrumental in increasing the percentage of people feel comfortable. PMV and PPD indices from Fanger’s comfort equation have been compared to the results of respondents’ thermal perception analysis; we noted that these indices are very sensitive to airspeed parameter.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : May we obtain thermal comfort with passive and low energy building? Study of thermal comfort in humid tropical classroom.
- Identifiant de la fiche : 30010399
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Indonésie; Consommation d'énergie; Immeuble; Température; Refroidissement passif; Enquête; École; Confort thermique
-
Passive cooling for school.
- Auteurs : JANSSENS H.
- Date : 05/2013
- Langues : Anglais
- Source : ASHRAE Journal - vol. 55 - n. 5
Voir la fiche
-
SEARCH II: assessment of energy use in 95 schoo...
- Auteurs : MAGYAR Z., NEMETH G., CALZONI J. A.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Thermal comfort in a large property portfolio: ...
- Auteurs : KIM J., DEUBLE M., CANDIDO C., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
From energy signature to cluster analysis: an i...
- Auteurs : PISTORE L., PERNIGOTTO G., CAPPELLETTI F., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 4th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Technical definition for nearly zero energy bui...
- Auteurs : KURNITSKI J.
- Date : 05/2013
- Langues : Anglais
- Source : REHVA Journal - vol. 50 - n. 3
Voir la fiche