Pompe à chaleur au propane à faible charge en frigorigène : une conception basée sur la simulation.
Bomba de calor de propano con baja carga de refrigerante: diseno basado en simulación.
Auteurs : OTT S.
Type d'article : Article
Résumé
This article is the Spanish translation of a paper presented at the 9th IEA Heat Pump Conference in Zurich (see the Bulletin of the IIR, reference 2009-0814). In the past, the so-called flammable refrigerants have already been used in heat pumps, but due to a low customer acceptance and a lacking support on the part of the compressor manufacturers most heat pumps have been shifted to conventional refrigerants. Reduced requirements on deployment for refrigeration cycles and heat pumps with refrigerant charges less than 150 g and the availability of first samples of cheap compressors for fridges and freezers with a higher cooling capacity (> 2 kW) made the production of small heat pumps using propane as refrigerant interesting again. Based on these conditions an exhaust air heat pump with a heating capacity of 2 kW for space and tap-water heating has been designed. To achieve a shorter developmental period the heat pump has initially been set up as a simulation. Modelica has been chosen as simulation environment using the refrigeration library TIL. Having a co-simulation with LabVIEW it has even been possible to implement complex control algorithms. The test results of a "real" heat pump that has been set up based on simulation results will be compared to the simulation results of the different levels of development of the refrigeration library.
Documents disponibles
Format PDF
Pages : pp. 44-51 (7 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Bomba de calor de propano con baja carga de refrigerante: diseno basado en simulación.
- Identifiant de la fiche : 2011-0313
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 37 - n. 412
- Date d'édition : 03/2009
Liens
- Voir les traductions : Propane heat pump with low refrigerant charge: a simulation based design.
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Hydrocarbures - Mots-clés : Air extrait; Conception; Air-eau; Simulation; Propane; Pompe à chaleur; Performance; COP; Frigorigène; Charge en frigorigène
-
Performance comparison of an air/water heat pum...
- Auteurs : GARCÍA-CASCALES J. R., ILLÁN GÓMEZ F., HIDALGO-MOMPEÁN F., et al.
- Date : 02/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
Voir la fiche
-
Étude expérimentale d'un chauffe-eau thermodyna...
- Auteurs : BYRNE P., BAZANTAY F., GHOUBALI R.
- Date : 03/2018
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - n.1168
Voir la fiche
-
The effect of the refrigerant charge amount on ...
- Auteurs : KIM D. H., PARK H. S., KIM M. S.
- Date : 04/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
Voir la fiche
-
Charge optimisation study of a reversible water...
- Auteurs : CORBERÁN J. M., MARTÍNEZ I. O., GONZÁLVEZ J.
- Date : 06/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 4
- Formats : PDF
Voir la fiche
-
Performance of a large capacity propane heat pu...
- Auteurs : CAVALLINI A., DA RIVA E., DEL COL D.
- Date : 03/2010
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 2
- Formats : PDF
Voir la fiche