Pompe à chaleur au propane à faible charge en frigorigène : une conception basée sur la simulation.
Propane heat pump with low refrigerant charge: a simulation based design.
Auteurs : OTT S.
Résumé
In the past, the so-called flammable refrigerants have already been used in heat pumps, but due to a low customer acceptance and a lacking support on the part of the compressor manufacturers most heat pumps have been shifted to conventional refrigerants. Reduced requirements on deployment for refrigeration cycles and heat pumps with refrigerant charges less than 150 g and the availability of first samples of cheap compressors for fridges and freezers with a higher cooling capacity (> 2 kW) made the production of small heat pumps using propane as refrigerant interesting again. Based on these conditions an exhaust air heat pump with a heating capacity of 2 kW for space and tap-water heating has been designed. To achieve a shorter developmental period the heat pump has initially been set up as a simulation. Modelica has been chosen as simulation environment using the refrigeration library TIL. Having a co-simulation with LabVIEW it has even been possible to implement complex control algorithms. The test results of a "real" heat pump that has been set up based on simulation results will be compared to the simulation results of the different levels of development of the refrigeration library.
Détails
- Titre original : Propane heat pump with low refrigerant charge: a simulation based design.
- Identifiant de la fiche : 2009-0814
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
- Date d'édition : 20/05/2008
Liens
- Voir les traductions : Bomba de calor de propano con baja carga de refrigerante: diseno basado en simulación.
Voir d'autres communications du même compte rendu (45)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Hydrocarbures - Mots-clés : Air extrait; Conception; Air-eau; Simulation; Propane; Pompe à chaleur; Performance; COP; Frigorigène; Charge en frigorigène
-
Bomba de calor de propano con baja carga de ref...
- Auteurs : OTT S.
- Date : 03/2009
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 37 - n. 412
- Formats : PDF
Voir la fiche
-
Charge and COP optimization of a reversible wat...
- Auteurs : MARTÍNEZ I. O., GONZÁLVEZ J., CORBERÁN J. M.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Charge minimization in a 30kW air to water heat...
- Auteurs : PALM B.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
New low charge heat pump using propane: design ...
- Auteurs : CAVALLINI A., DA RIVA E., DEL COL D.
- Date : 20/05/2008
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
Voir la fiche
-
Refrigerant charge minimization of a small geot...
- Auteurs : MONTAGUD C., MARTÍNEZ-GALVÁN I., GONZÁLVEZ-MACIÁ J., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.