PREVISION DE LA PERFORMANCE DES POMPES A CHALEUR EN REGIME CYCLIQUE AVEC UN MODELE DONT CHAQUE COMPOSANT PEUT ETRE ETUDIE ISOLEMENT ET COMPARAISON AVEC LES RESULTATS EXPERIMENTAUX.

PREDICTION OF CYCLIC HEAT PUMP PERFORMANCE WITH A FULLY DISTRIBUTED MODEL AND A COMPARISON WITH EXPERIMENTAL DATA.

Résumé

EN RAISON DE L'IMPORTANCE DES EFFETS DE LA DILATATION THERMIQUE ET DE LA COMPRESSIBILITE, ON APPLIQUE UN TRAITEMENT MATHEMATIQUE DETAILLE AU CONDENSEUR, A L'EVAPORATEUR ET A L'ACCUMULATEUR. ON DECRIT BRIEVEMENT LA METHODOLOGIE DE RESOLUTION EMPLOYEE. DES MODELESA PARAMETRES COMPOSES ONT ETE MIS AU POINT POUR LE DETENDEUR, LE MOTEUR A COMBUSTION INTERNE A GAZ NATUREL ET LE COMPRESSEUR. COMME ON A TROUVE QUE L'INTRODUCTION D'UN MODELE DE FRACTION DE VIDE APPROPRIE ETAIT ESSENTIELLE POUR DETERMINER EN DETAIL LA REPARTITION DE MASSE DU FRIGORIGENE, ON ETUDIE EGALEMENT CE SUJET. LES RESULTATS DE SIMULATION ET EXPERIMENTAUX CONCORDAIENT ASSEZ BIEN POUR LE FONCTIONNEMENT EN REGIME TRANSITOIRE D'UNE POMPE A CHALEUR HERMETIQUE EAU-EAU ET UN SYSTEME AIR-AIR AVEC COMPRESSEUR OUVERT.