Résumé
The demand of refrigerant at lower temperature by making use of solid/liquid latent heat is growing in the field of food transportation. However, because of the existence of supercooling, refrigerant cannot freeze at melting point. It must be cooled at lower temperature than the melting point. It needs high electrical load on refrigerator. Therefore, in order to reduce the high electrical load, a method of freezing supercooled solution using membrane is introduced. A capsule having solution with low concentration or tap water is installed in a package having refrigerant inside. One part of the capsule wall is made of membrane and only water can path through the membrane towards both inside and outside the capsule. Since the melting point inside the capsule is higher than the outside, solution in the capsule freeze first, and it propagates through the membrane and it becomes a trigger for the refrigerant to freeze. This study is a fundamental research on this propagation. So a sheet of membrane is put between refrigerant having high concentration and solution with low concentration, and they are cooled together. Parameters for the experiments were selected to be the difference in melting point, the location of initial ice appearance, cooling rate and membrane thickness. The results were compared and the effect and phenomena of these differences were investigated. As a result, following conclusions were obtained. Location of initial ice appearance and the membrane thickness influence the propagation, significantly. When a large difference in melting points exists, propagation effect through membrane is reduced.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Fundamental research on freezing of refrigerant by making use of membrane.
- Identifiant de la fiche : 30005155
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Date d'édition : 07/06/2010
Liens
Voir d'autres communications du même compte rendu (107)
Voir le compte rendu de la conférence
Indexation
-
Research on freezing of a refrigerant package w...
- Auteurs : OKAWA S., YAMADA T.
- Date : 01/07/2012
- Langues : Anglais
- Source : 10th International Conference on Phase-Change Materials and Slurries for Refrigeration and Air Conditioning. Proceedings: Kobe, Japan, July 29-August 1, 2012.
- Formats : PDF
Voir la fiche
-
Nano-powders migration and heat transfer charac...
- Auteurs : DING G. L., PENG H., HU H. T.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Small diameter effects on refrigerant charge in...
- Auteurs : VLASIE C., MACCHI H., JABBOUR O.
- Date : 26/08/2002
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
CFD simulation of fluid flow distribution in di...
- Auteurs : ZHANG Z., LI Y. Z., TIAN J. J.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche
-
Design and simulation of finned-tube heat excha...
- Auteurs : BENSAFI A., BORG S.
- Date : 08/1997
- Langues : Anglais
- Source : CLIMA 2000, Brussels 1997, August 30 to September 2, Congress Palace.
Voir la fiche