Résumé
Conventional defrost-mode fixes defrosting time-interval or defrosting starting temperature, but it is not a good defrosting method fit for all climates. A new defrost-mode called different-regions-defrost-mode selects optimal defrost-code for defrosting based on ambient air dry-bulb temperature. The influence of the different-regions-defrost-mode on an air-source heat pump chiller was investigated in this paper. The experiments for the new mode and the conventional mode were conducted on a nominal heating capacity 42 kW modular air-source heat pump and discussed. The experimental results show that the heating capacity could increased about 1.5 kW at low temperature by adopting an appropriate defrost code, and the more serious frost is, the more short defrosting time-interval is, but not less than that of the old defrost-mode; the more light frost is, the longer the defrosting time-interval is, even twice as long as that of the former defrost-mode.
Documents disponibles
Format PDF
Pages : ICR07-E2-558
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Research in different regions on a defrost mode for an air-source heat pump chiller.
- Identifiant de la fiche : 2008-0664
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Systèmes de dégivrage - Mots-clés : Chine; Air-eau; Procédé; Pompe à chaleur; Experimentation; Dégivrage
-
Expérience concernant l'efficacité d'une pompe ...
- Auteurs : WANG S., SHI Y., WU Q., et al.
- Date : 09/2007
- Langues : Chinois
- Source : Refrigeration - vol. 26 - n. 3
Voir la fiche
-
Dégivrage croisé du côté air de l'échangeur de ...
- Auteurs : WANG Z., CHEN S., YANG C.
- Date : 08/2008
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 29 - n. 4
- Formats : PDF
Voir la fiche
-
Badania odszraniania powietrznej pompy ciepla.
- Auteurs : HRYCYK E., ZAKRZEWSKI B.
- Date : 06/2010
- Langues : Polonais
- Source : Chlodnictwo - vol. 45 - n. 6
Voir la fiche
-
Naturumlauf-Abtauung für CO2-Luft/Wasser-Wärmep...
- Auteurs : MILDENBERGER J., KOSOWSKI K., LEMKE N., et al.
- Date : 05/2010
- Langues : Allemand
- Source : KI Kälte Luft Klimatechnik - vol. 46 - n. 5
Voir la fiche
-
Transient simulation of an air-source heat pump...
- Auteurs : LIU Z. Q., TANG G. F., ZHAO F. Y.
- Date : 22/04/2003
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
Voir la fiche