Document IIF

Recherche sur le système triple à pompe à chaleur aérothermique solaire.

Research on the triple system based on solar and air source heat pump.

Numéro : pap. 33

Auteurs : LIU Q., PAN H., CAI M.

Résumé

We submit a triple system based on solar and air source heat pump and establish steady-state operation mathematical model Based on the 60 m2 room in Wuhan city. We obtain the different system parameters under the cooling model, heating model, hot water supply model, cooling and hot water supply model, heating and hot water supply model, heating by hot water mode. It shows the high-performance, remarkable energy-saving effect, even in extreme weather, it still can meet the requirements.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Research on the triple system based on solar and air source heat pump.
  • Identifiant de la fiche : 30023382
  • Langues : Anglais
  • Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
  • Date d'édition : 06/04/2018
  • DOI : http://dx.doi.org/10.18462/iir.iccc.2018.0033

Liens


Voir d'autres communications du même compte rendu (72)
Voir le compte rendu de la conférence