Document IIF
Recommandations de conception pour des échangeurs de chaleur à plaques dans des pompes à chaleur utilisant des frigorigènes purs et mélangés.
Design recommendations for plate heat exchangers in heat pumps using pure and mixed refrigerants.
Numéro : pap. n. 853
Auteurs : MANCINI R., ZÜHLSDORF B., BRIX W., et al.
Résumé
This paper aims at deriving design recommendations for plate heat exchanger (PHE) evaporators and condensers in heat pump (HP) systems using different refrigerants. A coupled HP - PHE simulation framework was used to carry out cycle and component design for a case study, with different combinations of PHE geometrical parameters, and propane, butane and propylene/butane (0.5/0.5) as refrigerants. An operating model subsequently evaluated the heat pump thermodynamic and economic performance with the different designed PHEs: the trade-off between heat transfer area and refrigerant pressure drops was therefore taken into account for both components. Only evaporator pressure drops affected the Coefficient of Performance (COP), and different refrigerants presented dissimilar slopes of degradation. Condenser design did not influence the COP, and the economic optimum corresponded to the lowest size. The evaporator design at minimum cost was instead found as a trade-off between heat transfer area and pressure drops for all the working fluids. Despite the different rates of COP drop, the three refrigerants resulted in the same optimal pressure drop at the evaporator, equal to around 5 kPa.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Design recommendations for plate heat exchangers in heat pumps using pure and mixed refrigerants.
- Identifiant de la fiche : 30026488
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0853
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
Performance of heat pumps using pure and mixed ...
- Auteurs : MANCINI R., ZÜHLSDORF B., AUTE V., et al.
- Date : 08/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
Voir la fiche
-
Impact of liquid/vapor maldistribution on the p...
- Auteurs : MANCINI R., AUTE V., MARKUSSEN W. B., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental investigation of a heat pump tumbl...
- Auteurs : COP M., BARTA R. B., THOMAS C., HESSE U.
- Date : 02/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 158
- Formats : PDF
Voir la fiche
-
Analysis of high temperature heat pumps applyin...
- Auteurs : STAVSET O., BANASIAK K., HAFNER A.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Hydrocarbon refrigerants boiling local heat tra...
- Auteurs : LONGO G. A., MANCIN S., RIGHETTI G., ZILIO C.
- Date : 12/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - Vol. 156
- Formats : PDF
Voir la fiche