Réfrigérateur-congélateur à double régulation utilisant deux tubes capillaires et un système de commutation du débit d'air.

Dual-controlled indirect cooling refrigerator-freezer using two capillary tubes and an air flow switching system.

Résumé

The dual-controlled refrigeration system is devised to enhance the energy efficiency and basic performance of an indirect cooling household refrigerator-freezer. In order to alternately serve the fresh food and freezer compartment with a conventional simple refrigeration cycle, two capillary tubes and on/off valves are adopted. The air flow switching system, which is composed of two fans and dampers, is used to provide air flow for each compartment. The moter-driven on/off dampers are employed to switch the circulating path of air flowing through each compartment. Energy consumption was investigated.

Détails

  • Titre original : Dual-controlled indirect cooling refrigerator-freezer using two capillary tubes and an air flow switching system.
  • Identifiant de la fiche : 1999-3577
  • Langues : Anglais
  • Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
  • Date d'édition : 14/07/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (67)
Voir le compte rendu de la conférence