Refroidissement électronique à boucle fermée avec mise en oeuvre d'un jet incident monophasique et d'un échangeur de chaleur à minicanaux.
A closed-loop electronics cooling by implementing single-phase impinging jet and a mini-channel heat exchanger.
Auteurs : BINTORO J. S., AKBARZADEH A., MOCHIZUKI M.
Type d'article : Article
Résumé
This paper reports the authors' work in the design and testing of a closed-loop electronics cooling system that adopts bi-technologies: single phase impinging jet and a mini-channel heat exchanger. The system has the cooling capacity of 200 W over a single chip with a hydraulic diameter of 12 mm. The equivalent heat flux is 177 W/cm2. The cooling system maintains the chip's surface temperature below 95 °C maximum when the ambient temperature is 30 °C. De-ionized water is the working fluid of the system. For the impinging jet, two different nozzles are designed and tested. The hydraulic diameters are 0.5 and 0.8 mm. The corresponding volume flow rates are 280 and 348 mL/min. The mini-channel heat exchanger has 6 copper tubes with the inner diameter of 1.27 mm and the total length of about 1 m. The cooling system has a mini diaphragm pump and a DC electric fan with the maximum power consumptions of 8.4 and 0.96 W respectively. The COP of the system is 21.4.
Détails
- Titre original : A closed-loop electronics cooling by implementing single-phase impinging jet and a mini-channel heat exchanger.
- Identifiant de la fiche : 2006-0673
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 25 - n. 17-18
- Date d'édition : 12/2005
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Liquid cooling architectures for computer syste...
- Auteurs : ELLSWORTH M. J., SCHMIDT R. R.
- Date : 23/06/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
Voir la fiche
-
Airflow management in a liquid-cooled data center.
- Auteurs : CADER T., WESTRA L., REGIMBAL K., et al.
- Date : 25/06/2006
- Langues : Anglais
- Source : ASHRAE Transactions. 2006 Annual Meeting, Quebec City, Canada. Volume 112, part 2 + CD-ROM.
Voir la fiche
-
Silicon microchannel cooling for high power chips.
- Auteurs : COLGAN E. G., FURMAN B., GAYNES M., et al.
- Date : 12/2006
- Langues : Anglais
- Source : HVAC&R Research - vol. 12 - n. 4
Voir la fiche
-
Performance comparison of liquid-cooling with a...
- Auteurs : JEON J., KIM Y., CHOI J. M., et al.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Refrigerated cooling of microprocessors with mi...
- Auteurs : THOME J. R., BRUCH A.
- Date : 2008
- Langues : Anglais
- Source : The Institute of Refrigeration: annual proceedings. Volume 105, 2008-2009.
Voir la fiche