Résumé
The paper is based on a demonstration project in a medium-size supermarket situated in Roskilde, Denmark. The purpose of the project was to demonstrate the use of indirect cooling with ammonia in supermarkets substituting the existing CFC- and HCFC-based refrigeration plants. The existing installation includes 34 display cabinets connected to 34 separate refrigeration units. The new plant includes a 20 feet roof mounted container containing a low charge of two-stage ammonia refrigeration plant of 100 kilowatt cooling capacity and 40 kilowatt freezing capacity. The new plant is using the existing display cabinets and evaporators in the cold storage rooms. The distribution of cold is based on a dual circuit brine system in both cooling and freezing circuit. Measurements have been made both on the old and the new plant where power consumption measurements have corrected afterwards. The overall tendency of the comparison shows a significant improvement.
Documents disponibles
Format PDF
Pages : p 725-735
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Indirect cooling with ammonia in supermarkets.
- Identifiant de la fiche : 1999-2935
- Langues : Anglais
- Source : Natural Refrigerants, Energy Efficiency, Cost and Safety. Natural Working Fluids '98. IIR-Gustav Lorentzen Conference.
- Date d'édition : 02/06/1998
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (65)
Voir le compte rendu de la conférence
-
Performance tests results for display cases whe...
- Auteurs : HRNJAK P. S.
- Date : 02/10/1997
- Langues : Anglais
- Source : Compression systems with natural working fluids. International R&D on heat pump, air conditioning and refrigerating systems. Workshop proceedings.
Voir la fiche
-
Kohlendioxid CO2 (R744) als Tiefkühl-Kälteträger.
- Auteurs : SCHMUTZ B.
- Date : 18/11/1998
- Langues : Allemand
- Source : DKV-Tagungsbericht 25. 1998, Würzburg.
Voir la fiche
-
Erfahrungen mit Kälteträgersystemen in Supermär...
- Auteurs : HEGGLIN A.
- Date : 20/11/1996
- Langues : Allemand
- Source : DKV-Tagungsbericht 23. 1996 Leipzig.
Voir la fiche
-
Commercial refrigeration with ammonia and CO2 a...
- Auteurs : EGGEN G.
- Date : 02/10/1997
- Langues : Anglais
- Source : Compression systems with natural working fluids. International R&D on heat pump, air conditioning and refrigerating systems. Workshop proceedings.
Voir la fiche
-
Regelungskonzept für Eisbreianlagen in indirekt...
- Auteurs : DKV, BENDTSEN C., ZANGENBERG J.
- Date : 19/11/1997
- Langues : Allemand
- Source : DKV-Tagungsbericht 24. 1997, Hamburg.
Voir la fiche