Relations entre l'humidité de l'espace et l'humidité de l'isolation de la paroi intérieure du sous-sol avec et sans pare vapeur.
Space humidity/interior basement wall insulation moisture content relationships with and without vapour retarders.
Auteurs : GOLDBERG L. F., ALOI T.
Résumé
An interior basement wall finishing system consisting of mould/mildew resistant rigid fibreglass panels mounted in a polyvinyl chloride frame was tested experimentally over two heating seasons in a 5.9 m square foundation test module having hollow masonry block walls without any exterior waterproofing. Three vapour retarder configurations were tested, namely, no vapour retarder, a polyethylene vapour retarder on the interior side of the insulation, and a polyethylene vapour retarder on the wall side of the insulation. Conditioned basement interior conditions with temperature and relative humidity setpoints of 20 °C and 40 to 50%, respectively, were maintained over the first heating season. During the second heating season, the temperature was maintained at 13.3 °C with no dehumidification to emulate an unconditioned basement. During the intervening summer, the internal relative humidity ranged from 50 to 82%. A comprehensive set of transient and weekly manual data coupled with weekly observations of moisture conditions were collected. Under the particular "worst-case," cold-climate experimental conditions used, these data show that the no vapour retarder configuration has a stable annual wetting/drying cycle for a conditioned basement and allows the conservative inference of a stable annual wetting/drying cycle for an unconditioned basement as well, so indicating the suitability of this configuration for interior basement insulation. The internal vapour retarder configuration demonstrated an unstable annual wetting/drying cycle with a single episode of condensate pooling on the floor. The wall-side configuration also yielded a stable annual wetting/drying cycle but produced prolonged condensate pooling on the slab. Thus, neither of the latter two vapour retarder configurations was demonstrated experimentally to be appropriate for long-term usage with this interior basement insulation system.
Détails
- Titre original : Space humidity/interior basement wall insulation moisture content relationships with and without vapour retarders.
- Identifiant de la fiche : 2005-1393
- Langues : Anglais
- Source : IAQ 2001. Moisture, microbes and health effects: indoor air quality and moisture in buildings [CD-ROM].
- Date d'édition : 2002
Liens
Voir d'autres communications du même compte rendu (9)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air : généralités
- Mots-clés : Vapeur; Paroi; Matériau; Humidité; Isolation; Conditionnement d'air
-
Moisture, building enclosures, and mould.
- Auteurs : LSTIBUREK J.
- Date : 12/2001
- Langues : Anglais
- Source : HPAC Engineering - vol. 73 - n. 12
Voir la fiche
-
Indoor air quality and hygroscopically active m...
- Auteurs : STRAUBE J. F., DEGRAAUW J. P.
- Date : 2001
- Langues : Anglais
- Source : ASHRAE Transactions. 2001 Winter Meeting, Atlanta, GA. Volume 107, part 1 + CD-ROM.
Voir la fiche
-
Moisture permeability measurement using a surfa...
- Auteurs : YIK F. W. H., CHAU C. K.
- Date : 2002
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 23 - n. 1
Voir la fiche
-
Mineral fibre filled cavity wall: hygrothermal ...
- Auteurs : SIMPSON A., O'CONNOR D. E., STUCKES A. D.
- Date : 1991
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 12 - n. 4
Voir la fiche
-
An investigation of common thermal bridges in w...
- Auteurs : MCGOWAN A. G., DESJARLAIS A. O.
- Date : 1997
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche