RENTABILITE, ESSAI ET EVALUATION D'UNE POMPE A CHALEUR SUR L'AIR REJETE POUR DES MAISONS INDIVIDUELLES DE TYPE R-2000 (CONSTRUITES AVEC UN SOUCI D'HERMETICITE).

ECONOMICS, TESTING AND EVALUATION OF AN EXHAUST AIR HEAT PUMP FOR R2000 (TIGHT) HOUSES.

Auteurs : LINTON J. W.

Résumé

ON A EVALUE TROIS INSTALLATIONS EQUILIBREES DE RENOUVELLEMENT D'AIR : UN VENTILATEUR POUR L'AIR EXTRAIT ET L'AIR SOUFFLE, UN ECHANGEUR DE CHALEUR AIR-AIR ENTRE L'AIR EXTRAIT ET L'AIR NEUF, ET UNE POMPE A CHALEUR SUR L'AIR REJETE. CES INSTALLATIONS PEUVENT ETRE UTILISEES POUR AUGMENTER LE TAUX DE RENOUVELLEMENT D'AIR DANS DES MAISONS INDIVIDUELLES DE TYPE R-2000 (CONSTRUITES AVEC UN SOUCI D'HERMETICITE). ON A CONSTRUIT ET TESTE UN PROTOTYPE DE LA POMPE A CHALEUR SUR L'AIR REJETE, QUI UTILISE UN CALODUC ET UNE POMPE A CHALEUR. ON A EVALUE LA VERSION GIVRANTE ET LA VERSION NON GIVRANTE DE LA POMPE A CHALEUR SUR L'AIR REJETE. LA MEILLEURE PERFORMANCE GLOBALE A ETE OBTENUE AVEC LA VERSION NON GIVRANTE. LE COP DE L'UNITE NON GIVRANTE A ATTEINT UN MAXIMUM DE 4,8 A 263 K (-10 DEG C) ET UN MINIMUM DE 2,4 A 248 K (-25 DEG C).

Détails

  • Titre original : ECONOMICS, TESTING AND EVALUATION OF AN EXHAUST AIR HEAT PUMP FOR R2000 (TIGHT) HOUSES.
  • Identifiant de la fiche : 1989-2450
  • Langues : Anglais
  • Date d'édition : 1988
  • Source : Source : ASHRAE Trans.
    vol. 94; n. 2; 28-45; 10 fig.; 4 tabl.; 8 ref.; append.; discuss.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.