EXPERIENCES SUR LA REGULATION DE DEBIT DU FRIGORIGENE ET DE L'ECOULEMENT D'AIR EN REGIME PERMANENT POUR UNE POMPE A CHALEUR AIR-AIR A VITESSE VARIABLE DE FACON CONTINUE.

STEADY-STATE REFRIGERANT FLOW AND AIR FLOW CONTROL EXPERIMENTS FOR A CONTINUOUSLY VARIABLE SPEED AIR-TO-AIR HEAT PUMP.

Auteurs : MILLER W. A.

Résumé

UNE POMPE A CHALEUR POUR HABITATION A DEUX BLOCS AIR-AIR, A VITESSE POUVANT VARIER DE FACON CONTINUE, D'UNE PUISSANCE NOMINALE DE 9,7 KILOWATT A ETE MUNIE D'INSTRUMENTS ET ESSAYEE EN LABORATOIRE. LE COP, LA PUISSANCE DU SYSTEME ET LES RENDEMENTS DES COMPOSANTS ONT ETE MESURES EN MODEDE CHAUFFAGE ET DE REFROIDISSEMENT EN REGIME PERMANENT. LA VITESSE DU VENTILATEUR ET LE SOUS-REFROIDISSEMENT DU FRIGORIGENE A LA SORTIE DU CONDENSEUR ETAIENT MODIFIES A EP LES RESULTATS DES ESSAIS EN MODE DE CHAUFFAGE ET DE REFROIDISSEMENT ONT FAIT RESSORTIR UNE AMELIORATION DU COP DE 10 % POUR LE FONCTIONNEMENT AVEC ETRANGLEMENT PAR VARIATION DE LA SECTION (DETENDEUR) EN COMPARAISON D'UN ETRANGLEMENTPAR TUBE CAPILLAIRE.

Détails

  • Titre original : STEADY-STATE REFRIGERANT FLOW AND AIR FLOW CONTROL EXPERIMENTS FOR A CONTINUOUSLY VARIABLE SPEED AIR-TO-AIR HEAT PUMP.
  • Identifiant de la fiche : 1988-2461
  • Langues : Anglais
  • Date d'édition : 1987
  • Source : Source : ASHRAE Trans.
    vol. 93; n. 2; 1191-1204; 12 fig.; 2 tabl.; 8 ref.; discuss.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.