Réponse humaine au refroidissement local, convectif et rayonnant dans un environnement chaud.
Human response to local convective and radiant cooling in a warm environment.
Auteurs : MELIKOV A. K., KREJCIRÍKOVÁ B., KACZMARCZYK J., et al.
Type d'article : Article
Résumé
The response of 24 human subjects to local convective cooling, radiant cooling, and combined radiant and convective cooling was studied at 28°C and 50% relative humidity. The local cooling devices used were (1) a tabletop cooling fan, (2) personalized ventilation providing a stream of clean air, (3) radiant panels below and above the desk in front of the desk occupant, and (4) the same two radiant panels but with small fans blowing room air toward the upper panel to be cooled and redirected toward the person. A reference condition without cooling was also tested. The cooling devices significantly (p < 0.05) improved subjects’ thermal comfort compared to the condition without cooling. The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and perceived air quality increased when local cooling methods were used. The best results were achieved with personalized ventilation or the tabletop fan. Only minimal improvement in perceived air quality was reported when the radiant panel was used alone, indicating that in a warm environment, local convective cooling is superior to local radiant cooling as a means of improving perceived air quality. The intensity of the reported sick building syndrome symptoms increased during the exposure time, with or without cooling devices in operation. Air movement had very little effect on sick building syndrome symptoms, but they increased when the pollution level was high. The lowest prevalence of symptoms was reported with personalized ventilation and with the radiant panel with attached fans, which also caused subjects to report less fatigue. Sick building syndrome symptoms increased most when the tabletop fan, generating movement of polluted room air, was in operation. The temperature of the inhaled air rather than any local cooling of the head was associated with sick building syndrome symptoms, although this needs further study. The most preferred cooling method was personalized ventilation for six subjects, fan for eight subjects, and radiant panel (or radiant panel + fans) for nine subjects.
Détails
- Titre original : Human response to local convective and radiant cooling in a warm environment.
- Identifiant de la fiche : 30010568
- Langues : Anglais
- Source : HVAC&R Research - vol. 19 - n. 8
- Date d'édition : 11/2013
- DOI : http://dx.doi.org/10.1080/10789669.2013.842734
Liens
Voir d'autres articles du même numéro (2)
Voir la source
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Rayonnement; Climat humide; Refroidissement; Experimentation; Convection; Confort thermique; Climat chaud
-
Thermal environment of the low-exergy system co...
- Auteurs : TAKAHASHI I., TSUJII Y., ITOU N.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
The feasibility of performing high-temperature ...
- Auteurs : IYENGAR R. S., SABER E., MEGGERS F., et al.
- Date : 11/2013
- Langues : Anglais
- Source : HVAC&R Research - vol. 19 - n. 8
Voir la fiche
-
Postizanje termalnog komfora implementacijom ra...
- Auteurs : TAWEEKUN J., MEDOJEVIC M., PERIC M., et al.
- Date : 03/12/2014
- Langues : Anglais
- Source : Zbornik radova. 45. Medunarodnikongres i izložba o grejanju hladenju i klimatizaciji./ Proceedings. 45th International congress and exhibition on heating, refrigeration and air conditioning (HVAC&R).
- Formats : PDF
Voir la fiche
-
Condensation control of multi-zone DOAS + ceili...
- Auteurs : PAN Y., HUANG Z., LI Y., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Desiccant dehumidification with hydronic radian...
- Auteurs : AMEEN A., MAHMUD K.
- Date : 2005
- Langues : Anglais
- Source : ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
Voir la fiche