Document IIF

Résultats expérimentaux et étude d'un chauffe-eau à pompe à chaleur fonctionnant au CO2, à usage domestique.

Experimental results and evaluation of residential CO2 heat pump water heater.

Auteurs : MUKAIYAMA H., KUWABARA O., IZAKI K., et al.

Résumé

New components were designed for carbon dioxide and installed in the outdoor unit of an air conditioner. Nominal heat output is about 4 kW. COP was measured when hot water temperature was about 90 °C under several kinds of outdoor temperature and humidity conditions. Based on these experimental data, TEWI values were calculated. The CO2 heat pump water heater can reduce about 40% of the amount of CO2 produced, compared with boiler use.

Documents disponibles

Format PDF

Pages : 67-73

Document à numériser, disponible sous dix jours

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental results and evaluation of residential CO2 heat pump water heater.
  • Identifiant de la fiche : 2002-0057
  • Langues : Anglais
  • Source : Preliminary proceedings of the 4th IIR-Gustav Lorentzen Conference on natural working fluids at Purdue.
  • Date d'édition : 25/07/2000
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (5)
Voir le compte rendu de la conférence